GE Energy

4.3RS-232 Connections

The D400 accepts connections to RS-232 type devices through the RS-232 Adapter. The RS-232 Adapter (GE Part No. 520-0207) is a standard RS-232 serial I/O adapter card that plugs into any serial communication slot (slots 1 through 8) on the D400. It contains two independently isolated RS-232 serial ports (Port 1 and Port 2) each with a DB-9 connector.

The required RS-232 cable is a serial null modem, DB-9F to DB-9M cable. The cables must be shielded and DB-9 connector covers must provide EMC shielding (e.g. metalized plastic or die-cast metal covers).

See section “3.3 RS-232 Adapter” for configuration options.

»To connect RS-232 type devices to the RS-232 Adapter, use the following cable connection:

6

1

1

6

7

2

2

7

 

 

8

3

3

8

5

5

 

 

9

5

5

9

Relay

RS-232 Port DB-9 Connector Signal Definitions

Pin

DTE (default)

 

DCE

Number

Function

Signal Flow

Function

 

Signal Flow

 

 

 

 

 

 

 

 

1

DCD

IN

DCD

 

IN

 

 

 

 

 

 

2

RXD

IN

TXD

 

OUT

 

 

 

 

 

 

3

TXD

OUT

RXD

 

IN

 

 

 

 

 

 

4

DTR

OUT

DSR

 

IN

 

 

 

 

 

 

5

Signal GND

-

Signal GND

 

-

 

 

 

 

 

 

6

DSR

IN

DTR

 

OUT

 

 

 

 

 

 

7

RTS

OUT

CTS

 

IN

 

 

 

 

 

 

8

CTS

IN

RTS

 

OUT

 

 

 

 

 

 

9

Not connected

-

Not connected

 

-

 

 

 

 

 

 

48994-0089–1.00–2, General

Page 48
Image 48
GE 994-0089 user manual RS-232 Connections, Number Function Signal Flow