Baud Rate

Use this menu to configure the baud rate for Port 1. Rotate the Jog to select a baud rate from the menu.

Save changes and exit the menu: Press the Enter button.

Exit the menu without making changes: Press the Menu button.

Port 2

Use this menu to configure the baud rate for Port 2. Rotate the Jog to select a baud rate from the menu.

Save changes and exit the menu: Press the Enter button.

Exit the menu without making changes: Press the Menu button.

The RS232 port 2 is used for Event Generation and ASCII Text Insertion. See Section 7 for the RS232 Protocol required to perform these functions.

1200 Baud

2400 Baud

4800 Baud

9600 Baud

19200 Baud

38400 Baud

57600 Baud

1200 Baud

2400 Baud

4800 Baud

9600 Baud

19200 Baud

38400 Baud

57600 Baud

qMain Menu Communications RS485

Connect several units to a single keyboard, or vice-versa. Up to

32 units (any combination of multiplexers and keyboards) can be

networked together. Use this menu to specify the units unique network address.

Save changes and exit the menu: Press the Enter button.

Exit the menu without making changes: Press the Menu button.

Network Address

01

qMain Menu Communications Ethernet Settings

An ethernet connection can be used to connect to the unit from a PC for the viewing of live or recorded images. Use this menu to configure the Ethernet communications settings. Select from the following:

Ethernet: Select Enable or Disable.

Hostname: Not selectable. Pulled from the systems serial number.

DHCP: Select Enable or Disable. Enables dynamic IP addressing. When DHCP is enabled, the IP address, Subnet Mask, Gateway, and Server fields are dynamically addressed.

Name Service: Select from Disable or WINS. Enabling WINS registers the hostname and IP address within the current Network. This ensures that you can connect to the Triplex by hostname within the network.

IP Address / Subnet Mask / Gateway: Consult with a qualified Network Administrator or an MIS professional to configure these settings if DHCP is not enabled.

Ethernet Settings

Ethernet

: Enable

 

Hostname

: D406T2250419

 

DHCP

: Disable

 

Name Service

: Disable

 

IP Address

:

3.

18.173. 60

Subnet Mask

: 255.255.254.

0

Gateway

:

3.

18.172.

1

Primary Name Server

:

3.

18.173. 12

Backup Name Server

:

3.

18.173. 13

Print Server

:

3.

18.173. 11

TCP MTU Size

: Standard

 

[CANCEL]

 

[OK]

 

 

Primary Name Server / Backup Name Server: The IP addresses of the Primary and Backup Name Servers. Not required if DHCP is enabled.

Print Server: Enter the Print Servers IP address to enable the Print Image operation (Function and Zoom).

TCP MTU Size: Select from Standard, 1400, and 1200. The MTU describes the maximum possible TCP packet size. Standard (1500) is optimal for most ethernet network environments.