31
Installation Instructions

PROVIDE ADEQUATE

GAS SUPPLY

Your range is designed to operate at a pressure
of 4of water column on natural gas or, if
designed for LP gas (propane or butane),
10of water column.
Make sure you are supplying your range with
the type of gas for which it is designed.
This range is convertible for use on natural or
propane gas. If you decide to use this range on
LP gas, conversion must be made by a qualified
LP installer before attempting to operate the
range on that gas.
For proper operation, the pressure of natural
gas supplied to the regulator must be between
4and 13of water column.
For LP gas, the pressure supplied must be
between 10and 13of water column.
When checking for proper operation of the
regulator, the inlet pressure must be at least 1
greater than the operating (manifold) pressure
as given above.
The pressure regulator located at the inlet of the
range manifold must remain in the supply line
regardless of whether natural or LP gas is being
used.
A flexible metal appliance connector used to
connect the range to the gas supply line should
have an I.D. of 1/2and be 5 feet in length for
ease of installation.
1CONNECT THE RANGE TO GAS
Shut off the main gas supply valve before
disconnecting the old range and leave it off
until the new hookup has been completed.
Don’t forget to relight the pilot on other gas
appliances when you turn the gas back on.
Because hard piping restricts movement of the
range, the use of a CSA International-certified
flexible metal appliance connector is
recommended unless local codes
require a hard-piped connection.
Never use an old connector when installing a
new range. If the hard piping method is used,
you must carefully align the pipe; the range
cannot be moved after the connection is made.
To prevent gas leaks, put pipe joint compound
on, or wrap pipe thread tape with Teflon*
around, all male (external) pipe threads.
Install a manual gas line shut-off valve in
the gas line in an easily accessed location
outside of the range. Make sure everyone
operating the range knows where and how
to shut off the gas supply to the range.
Install male 1/2flare union adapter to the
1/2NPT internal thread at inlet of regulator.
Use a backup wrench on the regulator
fitting to avoid damage.
Install male 1/2or 3/4flare union adapter
to the NPT internal thread of the manual
shut-off valve, taking care to back-up the
shut-off valve to keep it from turning.
Connect flexible metal appliance connector
to the adapter on the range. Position range
to permit connection at the shut-off valve.
When all connections have been made,
make sure all range controls are in the off
position and turn on the main gas supply
valve. Use a liquid leak detector at all joints
and connections to check for leaks in the
system.
When using test pressures greater than 1/2 psig
to pressure test the gas supply system of the
residence, disconnect the range and individual
shut-off valve from the gas supply piping. When
using test pressures of 1/2 psig or less to test
the gas supply system, simply isolate the range
from the gas supply system by closing the
individual shut-off valve.
*Teflon: Registered trademark of DuPont
E
D
C
B
A
2
WARNING: DO NOT USE A FLAME
TO CHECK FOR GAS LEAKS.