STEP 10 SLIDE DUCT COVER DOWN

Installation Instructions

STEP 10 SLIDE DUCT COVER DOWN

SKIP THIS STEP IF USING THE SUPPLIED DUCT COVER

Hold the duct cover in place and remove the temporary stop screw. Return the screw to the storage location for future use.

Slide the lower duct cover down onto the hood.

 

Remove

Slide

Stop

Screw

Duct

 

Cover

 

Down

 

Stop Screw

Storage Location

STEP 11 INSTALL FILTERS

STEP 12 INSTALL RODS

Use a flat blade screwdriver to install stand-offs into the bottom of the hood.

Align implement rod to stand-offs with the screw hole towards the inside of the hood. Secure the rod to the stand-offs with the supplied Allen wrench.

Follow the same procedure on the opposite side.

Screw

Stand-offs

Into Hood

Use Allen Wrench to Secure Rod to Stand-offs

Place filter drip trays into the rear of the hood.

Insert the filter into the upper opening and drop into the trays.

To remove the filters, grasp the knobs and push the filter up and lift out.

17

Page 17
Image 17
GE ZV421, ZV541 Slide Duct Cover Down, Install Filters, Install Rods, Skip This Step If Using The Supplied Duct Cover