STEP 15 INSTALLATION CHECKLIST

Installation Instructions

STEP 15 INSTALLATION CHECKLIST

Check Blower Safety Screw

Ensure that blower safety screw is securely tightened. See page 16, Step 9. If screw is missing, order replacement parts bag.

Check Operating Sound and Proper Air-Flow

Turn blower to each speed setting and listen for rattles and vibration. You should notice an audible difference at each speed setting.

Check for foreign material in transition.

Check that blower screen is not damaged or pushed into the blower impeller.

The damper should move freely. Listen for opening and closing while turning the unit on and off.

Check that the damper is not damaged, does not vibrate and that damper bumper pads are in place. Order a damper replacement assembly if needed.

Check that ductwork is 10" round. If duct type is not rigid and less than 10" round, inform the consumer that performance will be reduced.

Check Lighting Function

Check that power cable is plugged into the junction box on top of the hood.

Turn halogen lamps to each setting. Note change in brightness at different settings.

Check that each lamp bezel is secure. Turn to the right to tighten. Order replacement lamp bezel and socket assemblies if needed.

Check appearance and installation

Use a spirit level to check that the hood is level. Review installation instructions to determine source of problem.

Top covers (if used) should lay flat in the recess on top of the hood. Make sure side tabs are engaged in slots and the cover is secured with two screws.

Clean the hood surfaces and all filters. See the Owner’s Manual for cleaning instructions. They should be free of construction debris such as sawdust.