INSTALLATION HEIGHT REQUIREMENTS

Advance Planning

INSTALLATION HEIGHT REQUIREMENTS

These vent hoods must be installed 30" min. and 36" max. above the cooking surface – regardless of the ceiling height. Therefore, installation height of the hood depends on the exact ceiling height of the kitchen.

Accessories are available for ceiling heights 8’6" and up to 10’4".

Example: Hood installation height with 8 ft. ceilings.

8 ft. Ceiling

8 ft. Ceiling

9"

5"

Supplied

Supplied

Duct

Duct

Cover

Cover

31"31"

ZV42I

 

ZV54I

Both models are shipped with a support frame and duct cover for 7’11" to 8’5" ceilings.

If the ceiling height is 7’11", the installation height above the cooking surface will be 30".

If the ceiling height is 8’5", the hood installation height will be 36".

DETERMINE INSTALLATION HEIGHT

1.Measure the exact ceiling height.

2.Review the chart to determine the range of hood installation heights that can be accomplished with or without an accessory kit.

Duct Cover

20" for ZV42I 24" for ZV54I

 

 

Ceiling

 

30" Min. and 36" Max.

Height

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

36"

to

Countertop

ACCESSORIES

ZX42DC10 – Optional Accessory for ZV42I. ZX54DC10 – Optional Accessory for ZV54I.

Accessories for ceiling heights of 8’6" to 10’4". Includes telescoping support frames and duct covers.

 

 

 

 

 

 

 

Model ZV42I

 

 

 

 

Actual

 

 

 

 

 

Chimney Length at

 

 

Duct

 

 

Ceiling

 

 

 

 

 

Hood Installation Height

 

Cover

 

Height

30"

31"

32"

33"

34"

 

35"

36"

Kit

 

 

10’4"

 

 

 

 

 

36

35

34

 

33

32

Order

 

10’3"

 

 

 

 

36

35

34

33

 

32

31

 

10’2"

36

35

34

33

32

 

31

30

ZX42DC10

 

10’1"

35

34

33

32

31

 

30

29

Use Long

 

10’

34

33

32

31

30

 

29

28

Support

 

9’11"

33

32

31

30

29

 

28

27

and

 

9’10"

32

31

30

29

28

 

27

26

Duct Cover

 

9’9"

31

30

29

28

27

 

26

25

 

 

 

9’8"

30

29

28

27

26

 

25

24

 

 

 

9’7"

29

28

27

26

25

 

24

23

 

 

 

9’6"

28

27

26

25

24

 

23

22

Order

 

9’5"

27

26

25

24

23

 

22

21

 

9’4"

26

25

24

23

22

 

21

20

ZX42DC10

 

9’3"

25

24

23

22

21

 

20

19

Use Short

 

9’2"

24

23

22

21

20

 

19

18

Support

 

9’1"

23

22

21

20

19

 

18

17

and

 

9’

 

22

21

20

19

18

 

17

16

Duct Cover

 

8’11"

21

20

19

18

17

 

16

15

 

 

 

8’10"

20

19

18

17

16

 

15

 

 

 

 

8’9"

19

18

17

16

15

 

 

 

 

 

 

8’8"

18

17

16

15

 

 

 

 

 

 

 

8’7"

17

16

15

 

 

 

 

 

 

 

 

8’6"

16

15

 

 

 

 

 

 

 

 

 

8’5"

15

 

 

 

 

 

 

9

Use

 

8’4"

 

 

 

 

 

 

 

 

 

9

 

 

8’3"

 

 

 

 

 

 

 

9

 

 

 

Supplied

 

8’2"

 

 

 

 

 

 

9

 

 

 

 

Support

 

8’1"

 

 

 

 

 

9

 

 

 

 

 

and

 

8’

 

 

 

 

9

 

 

 

 

 

 

Duct Cover

 

7’11"

 

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model ZV54I

 

 

 

 

Actual

 

 

 

 

 

Chimney Length at

 

 

Duct

 

Ceiling

 

 

 

 

 

Hood Installation Height

 

Cover

 

Height

30"

31"

32"

33"

34"

 

35"

36"

Kit

 

 

10’4"

 

 

 

 

 

 

 

 

 

 

28

Order

 

10’3"

 

 

 

 

 

 

 

 

 

28

27

 

10’2"

 

 

 

 

 

 

 

28

 

27

26

ZX54DC10

 

10’1"

 

 

 

 

 

 

28

27

 

26

25

Use Long

 

10’

 

 

 

 

 

28

27

26

 

25

24

Support

 

9’11"

 

 

 

 

28

27

26

25

 

24

23

and

 

9’10"

28

27

26

25

24

 

23

22

Duct Cover

 

9’9"

27

26

25

24

23

 

22

21

 

 

 

9’8"

26

25

24

23

22

 

21

20

 

 

 

9’7"

25

24

23

22

21

 

20

19

 

 

 

9’6"

24

23

22

21

20

 

19

18

 

 

 

9’5"

23

22

21

20

19

 

18

17

Order

 

9’4"

22

21

20

19

18

 

17

16

 

9’3"

21

20

19

18

17

 

16

15

ZX54DC10

 

9’2"

20

19

18

17

16

 

15

14

Use Short

 

9’1"

19

18

17

16

15

 

14

13

Support

 

9’

18

17

16

15

14

 

13

12

and

 

8’11"

17

16

15

14

13

 

12

 

Duct Cover

 

8’10"

16

15

14

13

12

 

 

 

 

 

 

8’9"

15

14

13

12

 

 

 

 

 

 

 

8’8"

14

13

12

 

 

 

 

 

 

 

 

8’7"

13

12

 

 

 

 

 

 

 

 

 

8’6"

12

 

 

 

 

 

 

 

 

 

 

8’5"

 

 

 

 

 

 

 

 

 

 

5

Use

 

8’4"

 

 

 

 

 

 

 

 

 

5

 

Supplied

 

8’3"

 

 

 

 

 

 

 

5

 

 

 

Support

 

8’2"

 

 

 

 

 

 

5

 

 

 

 

and

 

8’1"

 

 

 

 

 

5

 

 

 

 

 

Duct Cover

 

8’

 

 

 

 

5

 

 

 

 

 

 

 

 

 

7’11"

 

5

 

 

 

 

 

 

 

 

 

6

Page 6
Image 6
GE ZV541, ZV421 Determine Installation Height, Installation Height Requirements, Accessories, Advance Planning