Advanced Operation

Commands

#use_discovery

Enables or disables discovery access mode. If this mode is disabled, then the

IP to 2 x RS-232 Converter will not be discoverable when using the Gefen Discovery Tool. The default setting is enabled.

Syntax

#use_discovery param1

Parameters

param1State

State Description

0Discovery access disabled

1Discovery access enabled

Example

#use_discovery 1

Discovery Access is set to Enabled