Maintenance

Maint

Maintenance

Maintenance Tasks

Task Completed

level

Interval

Date/lnitials

 

 

 

 

 

 

 

1. Disable the unit from operating per the first page warning.

 

 

 

 

 

 

 

2. Check the engine oil level. Adjust as necessary.

 

 

 

 

 

 

 

3. Check the engine coolant level. Adjust as necessary.

 

 

 

 

 

 

 

4. Check the engine coolant thermal protection level. Correct as neces-

 

 

 

sary.

 

 

 

 

 

 

 

5. Check the diesel fuel supply level. Adjust as necessary.

 

 

 

 

 

 

Every 12 months

6. Drain water and sediment from the diesel fuel tank.

 

 

 

 

 

or

7. Drain water from the diesel fuel line water separator if unit is equipped

 

 

100 hours of

with one.

 

3

operation

8. Check the air inlets and outlets for debris. Clean as necessary.

 

 

 

 

 

 

 

(Requires

9. Check the battery electrolyte level if accessible. Adjust as

 

 

necessary.

 

 

approximately

 

 

 

 

 

4,0 man hours

10. Check the battery posts, cables, and charger for loose connections,

 

 

per unit)

 

 

corrosion, and proper operation. Correct as necessary.

 

 

 

 

 

 

 

 

 

 

11. Check the unit wiring for loose connections, corrosion, and damage.

 

 

 

Correct as necessary.

 

 

 

 

 

 

 

12. Check the engine accessory drive belts for wear, weather cracking,

 

 

 

and damage. Replace as necessary.

 

 

 

 

 

 

 

13. Test the unit safety devices (alarms, shutdowns, etc.) for proper

 

 

 

operation. Correct and/or adjust as necessary.

 

 

 

 

 

 

 

14. Perform an oil analysis (send asample to a lab for results). Change the

 

 

 

engine oil and filters if the analysis results indicate this is required.

 

 

 

 

 

 

 

15. Visually inspect the unit looking for leaks, wear or damage, loose

 

 

 

connections or components, and corrosion. Correct as necessary.

 

 

 

 

 

 

 

16. Start and exercise the unit under full rated load for at least 2 hours look-

 

 

 

ing for leaks, loose connections or components, and abnormal operating

 

 

 

conditions. Correct as necessary.

 

 

 

17. Return the unit to standby setup for operation when required.

 

 

 

 

 

Technician'sSignature

Date Inspection Completed

Unit Hour Meter Reading at Completion of the Inspection