Section 2.1

GENERAL INFORMATION

Engine crankcase oil capacity without oil filter change is about 29 fluid ounces (850m.

Engine crankcase oil capacity (with oil filter change) is about 1 U.S. quart (946m1).

Change engine oil and the oil filter after the first eight

(8)hours of operation. Thereafter, change engine oil and oil filter every 50 operating hours.

NOTE: Additional Information on the engine oil system can be found in Part 5 of this manual, "Engine Oil and Cooling System".

STORAGE INSTRUCTIONS

PREPARATION FOR STORAGE:

The engine should be started at least once every seven (7) days and allowed to run for at least thirty

(30)minutes. If this cannot be done and the engine is to remain unused longer than thirty (30) days, it must be prepared for storage. To prepare the unit for stor- age, proceed as follows:

1.Start the engine and let it warm up.

2.After engine is thoroughly warmed up, shut it down.

NOTE: If the unit is equipped with a gasoline fuel system and GASOHOL was used as a fuel, turn off the supply of fuel to the engine and let It run out of gas.

3.While engine is still warm from running, completely drain the oil. Then, refill with the recommended oil. See "Recommended Engine Oil".

4.Attach a tag to the engine indicating the viscosity and classifi- cation of the oil in the crankcase.

5.Remove the spark plug and pour about one (1) ounce (15m1) of clean, fresh engine oil into the spark plug threaded opening. Crank the engine several times to distribute the oil, then install and tighten the spark plug.

6.Remove the battery and store it in a cool, dry room on a wood- en board. Never store the battery on any concrete or wood floor.

7.Clean and wipe the generator exterior surfaces.

RETURN TO SERVICE AFTER STORAGE:

To return the unit to service after storage, proceed as follows:

1.Verify that the correct oil is in the engine crankcase by check- ing the tag on the engine (see "Recommended Engine Oil".) If necessary, drain oil and refill with the recommended oil.

2.Check the battery. Fill all battery cells to the proper level with distilled water. DO NOT USE TAP WATER IN THE BATTERY. If necessary, recharge the battery to a 100 percent state of charge or replace it, if defective.

3.Turn OFF all electrical loads. Start the engine at no load and let it warm up.

4.Apply electrical loads to at least 50% of the unit's rated capacity.

5.When engine is thoroughly warmed up, turn off or disconnect all electrical loads. Then, shut the engine down.

THE UNIT IS NOW READY FOR SERVICE.

ENGINE TUNE-UP

The following procedure may be used as a minor tune-up. On completion of the procedure, the engine should run properly. If it does not run properly, addi- tional checks and repairs are required.

1.Service and repair engine air cleaners, as necessary.

2.Check engine oil level and condition of oil. Add or change oil as required.

3.Remove shrouding and clean away dirt from the engine cylin- der head and cooling fins.

4.Check fuel filters and clean or replace as necessary.

5.Replace the spark plug with a Champion RC12YC (or equiva- lent) plug.

a.Set spark plug gap to 0.030 inch (0.76mm).

b.Install new plug and tighten to 13 foot-pounds (1.8 N-m).

c.If a torque wrench is not available, tighten spark plug as tight as possible with fingers and then

(1)If plug Is RE-USED, tighten about 1/4 turn more with a wrench.

(2)If plug is NEW, tighten it about 1/2 turn more with a wrench.

6.Check that wiring is free of breaks, abrasions and are properly routed.

7.Check for spark as outlined in "Ignition" section of Part 6 of this manual.

8.Run engine, adjust carburetor if necessary and check opera- tion.

Page 2.1-3

Page 39
Image 39
Generac Power Systems 941-2 Storage Instructions, Engine TUNE-UP, Preparation for Storage, Return to Service After Storage

941-2, 940-2 specifications

Generac Power Systems has established a strong reputation in the field of backup power solutions, particularly with its innovative products like the Generac 940-2 and 941-2 generator systems. These generators are designed to provide reliable power during emergencies, ensuring that homes and businesses can maintain operations seamlessly when grid power is disrupted.

One of the standout features of the Generac 940-2 and 941-2 models is their robust engine performance. Both generators utilize Generac’s patented engines, known for their durability and efficiency. These engines are built to withstand the most demanding conditions while providing a consistent power output. This reliability is crucial for users who depend on uninterrupted power supply for essential appliances and equipment.

In terms of technologies, the Generac 940-2 and 941-2 are equipped with advanced automatic transfer switch capabilities. This technology allows the generators to automatically start and supply power within seconds of an outage. This quick response time helps to ensure that critical systems remain operational without noticeable interruptions, which is vital for businesses and households alike.

Another important characteristic of these models is their user-friendly interface. The generators come with an intuitive digital controller that provides real-time information on power usage, system status, and maintenance needs. This technology makes it easy for users to monitor their generators and ensure they are always ready for an emergency.

The design of the Generac 940-2 and 941-2 also emphasizes noise reduction and aesthetic appeal. These units are engineered for quieter operation compared to traditional generators, making them suitable for residential areas. Their sleek appearance also fits well with modern home exteriors, enhancing rather than detracting from the property’s visual appeal.

Furthermore, these generators offer flexible fuel options, with the ability to run on natural gas or propane. This versatility allows users to choose the fuel source that best meets their needs, contributing to energy efficiency and lowering overall operating costs.

In summary, the Generac Power Systems 940-2 and 941-2 are exceptional generators that combine powerful performance with innovative technologies. Their automatic transfer switch capabilities, user-friendly controls, noise reduction features, and flexible fuel options make them an excellent choice for anyone seeking reliable backup power solutions. With these generators, users can rest assured knowing they have a dependable energy source ready when they need it most.