POST (hex)

 

Debug Code Action

 

BIOS Program Definition

 

Possible Cause

 

Solution

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C1

 

00 -> C0 -> Stopped at C1

 

Detecting memory.

1. Incompatible memory modules.

1.

Remove and reinstall the memory

 

 

 

(00 -> C0 -> C1 ->

 

 

 

 

 

modules.

 

 

 

Reset -> Looping)

 

Detecting DRAM size and type.

 

 

 

 

 

 

2. Overclocking issue (tight DRAM

2.

Clear the CMOS then load the

 

 

 

 

 

ECC auto-detection of L2 cache.

 

 

 

 

 

 

 

timing).

 

default speed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.

One of the memory modules is

3.

Try installing a single module only.

 

 

 

 

 

 

 

defective.

 

 

 

 

 

 

 

 

 

 

 

 

C3/C5

 

C0 -> C1 -> Stopped at C3/C5

 

Expanding compressed BIOS code to

1. Tight DRAM timing (system is

1.

Clear the CMOS then load the

 

 

 

(C0 -> C1 -> C3 ->

 

the DRAM.

 

unstable).

 

default speed.

 

 

 

Reset -> Looping)

 

 

 

 

 

 

 

 

 

 

 

2.

Insufficient DRAM voltage.

2.

Increase the DRAM’s voltage.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.

Overclocking issue.

3.

Remove and reinstall the memory

 

 

 

 

 

 

 

 

 

modules.

 

 

 

 

 

 

 

 

 

 

CF

 

Shutdown -> Stopped at CF

 

Resume on S1/S3 failed.

1. Insufficient DRAM voltage.

1.

Increase the DRAM’s voltage.

 

 

 

(Shutdown -> CF -> Reset)

 

 

 

 

 

 

 

 

 

 

 

2.

Incompatible memory modules.

2.

Remove and reinstall the memory

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

modules.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.

Overclocking issue (tight DRAM

3.

Load the default DRAM speed.

 

 

 

 

 

 

 

timing).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4.

BIOS issue.

4.

Upgrade to the latest BIOS.

 

 

 

 

 

 

 

 

 

 

E0

 

C0 -> C1 -> Stopped at E0

 

E0-EF Definition: Initializing PCIE

1. Mixed-up BIOS data.

1.

Clear the CMOS data.

 

 

 

 

 

device check code.

 

 

 

 

 

 

 

 

 

2.

Incompatible PCI devices.

2.

Remove and reinstall the PCI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

device.

 

 

 

 

 

 

 

 

 

 