Goodmans GPC 13 SEER R-410A COOLING PERFORMANCE DATA GPC1330H41AA, Expanded Performance Data

Models: GPC1324H41A GPC 13 SEER R-410A

1 47
Download 47 pages 14.36 Kb
Page 16
Image 16
MODEL: GPC1330H41A*

16

MODEL: GPC1330H41A*

EXPANDED PERFORMANCE DATA

COOLING OPERATION

Design Subcooling, 12±3 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 8±3 °F @ the compressor suction access fitting connection.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor Ambient Temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

65

 

 

75

 

 

 

 

85

 

 

95

 

 

 

105

 

 

115

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Entering Indoor Wet

Bulb Temperature

 

 

 

 

 

 

 

 

 

 

IDB*

Airflow

 

59

63

 

67

71

59

63

 

67

71

59

63

 

67

71

59

63

 

67

71

59

63

67

71

59

63

67

71

 

 

MBh

28.2

29.3

 

32.0

-

27.6

28.6

 

31.3

-

26.9

27.9

 

30.6

-

26.3

27.2

 

29.8

-

24.9

25.8

28.3

-

23.1

23.9

26.2

-

 

 

S/T

0.79

0.66

0.46

-

0.82

0.68

 

0.47

-

0.84

0.70

0.49

-

0.87

0.72

 

0.50

-

0.90

0.75

0.52

-

0.91

0.76

0.53

-

 

 

Delta T

17

15

11

-

18

15

 

12

-

18

15

12

-

18

15

 

12

-

17

15

11

-

16

14

11

-

 

1180

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KW

2.07

2.11

2.17

-

2.22

2.26

 

2.33

-

2.35

2.40

2.47

-

2.46

2.52

 

2.59

-

2.56

2.62

2.70

-

2.65

2.70

2.79

-

 

 

AMPS

8.8

9.0

9.2

-

9.4

9.6

 

9.8

-

10.0

10.2

10.5

-

10.6

10.8

 

11.1

-

11.2

11.4

11.8

-

11.8

12.0

12.4

-

 

 

HI PR

232

249

263

-

260

280

 

295

-

296

318

336

-

337

362

 

382

-

379

407

430

-

418

450

475

-

 

 

LO PR

111

118

129

-

118

125

 

137

-

122

130

142

-

128

137

 

149

-

135

143

156

-

139

148

162

-

 

 

MBh

27.4

28.4

31.1

-

26.8

27.7

 

30.4

-

26.1

27.1

29.7

-

25.5

26.4

 

28.9

-

24.2

25.1

27.5

-

22.4

23.2

25.5

-

 

 

S/T

0.75

0.63

0.44

-

0.78

0.65

 

0.45

-

0.80

0.67

0.46

-

0.83

0.69

 

0.48

-

0.86

0.72

0.50

-

0.87

0.72

0.50

-

 

 

Delta T

18

16

12

-

18

16

 

12

-

18

16

12

-

18

16

 

12

-

18

16

12

-

17

15

11

-

70

1050

KW

2.05

2.09

2.16

-

2.20

2.25

 

2.31

-

2.33

2.38

2.45

-

2.45

2.50

 

2.57

-

2.54

2.60

2.68

-

2.63

2.68

2.77

-

 

 

AMPS

8.7

8.9

9.1

-

9.3

9.5

 

9.8

-

10.0

10.2

10.5

-

10.5

10.8

 

11.1

-

11.1

11.3

11.7

-

11.7

11.9

12.3

-

 

 

HI PR

229

247

261

-

257

277

 

292

-

293

315

332

-

333

359

 

379

-

375

403

426

-

414

446

471

-

 

 

LO PR

110

117

128

-

116

124

 

135

-

121

129

141

-

127

135

 

148

-

133

142

155

-

138

147

160

-

 

 

MBh

25.3

26.2

28.7

-

24.7

25.6

 

28.1

-

24.1

25.0

27.4

-

23.5

24.4

 

26.7

-

22.3

23.2

25.4

-

20.7

21.5

23.5

-

 

 

S/T

0.73

0.61

0.42

-

0.75

0.63

 

0.44

-

0.77

0.65

0.45

-

0.80

0.67

 

0.46

-

0.83

0.69

0.48

-

0.83

0.70

0.48

-

 

920

Delta T

18

16

12

-

19

16

 

12

-

19

16

12

-

19

16

 

12

-

18

16

12

-

17

15

11

-

 

KW

2.01

2.05

2.11

-

2.15

2.19

 

2.26

-

2.28

2.32

2.39

-

2.39

2.44

 

2.51

-

2.48

2.53

2.61

-

2.56

2.62

2.70

-

 

 

AMPS

8.5

8.7

8.9

-

9.1

9.3

 

9.5

-

9.7

9.9

10.2

-

10.3

10.5

 

10.8

-

10.9

11.1

11.4

-

11.4

11.6

12.0

-

 

 

HI PR

222

239

253

-

250

269

 

284

-

284

305

322

-

323

348

 

367

-

364

391

413

-

402

432

457

-

 

 

LO PR

107

114

124

-

113

120

 

131

-

117

125

136

-

123

131

 

143

-

129

137

150

-

134

142

155

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MBh

28.7

29.5

32.0

34.3

28.0

28.9

 

31.2

33.5

27.4

28.2

30.5

32.7

26.7

27.5

 

29.8

31.9

25.4

26.1

28.3

30.3

23.5

24.2

26.2

28.1

 

 

S/T

0.90

0.80

0.61

0.39

0.93

0.83

 

0.63

0.41

0.95

0.85

0.65

0.42

0.99

0.88

 

0.67

0.43

1.00

0.91

0.69

0.45

1.00

0.92

0.70

0.45

 

1180

Delta T

20

19

15

10

20

19

 

15

11

20

19

15

11

20

19

 

15

11

20

19

15

11

18

17

14

10

 

KW

2.08

2.13

2.19

2.25

2.23

2.28

 

2.35

2.42

2.37

2.42

2.49

2.57

2.48

2.54

 

2.62

2.70

2.58

2.64

2.72

2.81

2.67

2.73

2.81

2.91

 

 

AMPS

8.9

9.0

9.3

9.6

9.4

9.6

 

9.9

10.2

10.1

10.3

10.6

11.0

10.7

10.9

 

11.2

11.6

11.3

11.5

11.9

12.2

11.9

12.1

12.5

12.9

 

 

HI PR

234

252

266

277

262

282

 

298

311

299

321

339

354

340

366

 

386

403

382

412

435

453

423

455

480

501

 

 

LO PR

112

120

131

139

119

126

 

138

147

123

131

143

153

130

138

 

151

160

136

145

158

168

141

150

163

174

 

 

MBh

27.9

28.7

31.1

33.3

27.2

28.0

 

30.3

32.6

26.6

27.4

29.6

31.8

25.9

26.7

 

28.9

31.0

24.6

25.4

27.4

29.5

22.8

23.5

25.4

27.3

 

 

S/T

0.86

0.77

0.58

0.37

0.89

0.79

 

0.60

0.39

0.91

0.81

0.62

0.40

0.94

0.84

 

0.64

0.41

0.98

0.87

0.66

0.42

0.98

0.88

0.67

0.43

75

1050

Delta T

21

19

16

11

21

19

 

16

11

21

20

16

11

21

20

 

16

11

21

19

16

11

20

18

15

10

KW

2.07

2.11

2.17

2.24

2.22

2.26

 

2.33

2.40

2.35

2.40

2.47

2.55

2.47

2.52

 

2.60

2.68

2.56

2.62

2.70

2.79

2.65

2.71

2.79

2.88

 

 

AMPS

8.8

9.0

9.2

9.5

9.4

9.6

 

9.8

10.1

10.0

10.3

10.5

10.9

10.6

10.8

 

11.2

11.5

11.2

11.4

11.8

12.2

11.8

12.0

12.4

12.8

 

 

HI PR

232

249

263

275

260

280

 

295

308

296

318

336

350

337

362

 

383

399

379

408

430

449

418

450

475

496

 

 

LO PR

111

118

129

138

118

125

 

137

145

122

130

142

151

128

137

 

149

159

135

143

156

166

139

148

162

172

 

 

MBh

25.7

26.5

28.7

30.8

25.1

25.9

 

28.0

30.0

24.5

25.2

27.3

29.3

23.9

24.6

 

26.7

28.6

22.7

23.4

25.3

27.2

21.1

21.7

23.5

25.2

 

 

S/T

0.83

0.74

0.56

0.36

0.86

0.77

 

0.58

0.37

0.88

0.79

0.59

0.38

0.91

0.81

 

0.61

0.39

0.94

0.84

0.64

0.41

0.95

0.85

0.64

0.41

 

920

Delta T

21

20

16

11

21

20

 

16

11

22

20

16

11

22

20

 

16

11

21

20

16

11

20

18

15

10

 

KW

2.02

2.06

2.12

2.19

2.17

2.21

 

2.28

2.35

2.29

2.34

2.41

2.49

2.41

2.46

 

2.53

2.61

2.50

2.56

2.64

2.72

2.59

2.64

2.72

2.81

 

 

AMPS

8.6

8.8

9.0

9.3

9.2

9.3

 

9.6

9.9

9.8

10.0

10.3

10.6

10.4

10.6

 

10.9

11.2

10.9

11.2

11.5

11.9

11.5

11.7

12.1

12.5

 

 

HI PR

225

242

255

266

252

271

 

286

299

287

309

326

340

327

351

 

371

387

367

395

417

435

406

437

461

481

 

 

LO PR

108

115

125

134

114

121

 

132

141

119

126

138

147

125

132

 

145

154

130

139

152

161

135

144

157

167

 

* IDB: Entering Indoor Dry Bulb Temperature

 

 

 

NOTE: Shaded area is ACCA (TVA) conditions

 

 

 

 

 

 

 

 

 

 

 

 

High and low pressures are measured at the liquid and suction access fittings.

COOLING PERFORMANCE DATA

GPC1330H41AA

Page 16
Image 16
Goodmans GPC 13 SEER R-410A COOLING PERFORMANCE DATA GPC1330H41AA, Expanded Performance Data, MODEL GPC1330H41A

FAQ

What is the design subcooling for the GPC1330H41A air conditioner?

The design subcooling for the GPC1330H41A air conditioner is 123 F at the liquid access fitting connection.

What are the cooling performance data available for the GPC1330H41A model?

The cooling performance data for the GPC1330H41A model includes high and low pressure measurements, design subcooling, and superheat values at various outdoor ambient temperatures.

How are the high and low pressures measured for the GPC1330H41A air conditioner?

The high and low pressures for the GPC1330H41A air conditioner are measured at the liquid and suction access fittings.