MODEL: GPC1324H41A*

 

 

 

 

 

EXPANDED PERFORMANCE DATA

 

 

 

COOLING OPERATION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor Ambient Temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

65

 

 

 

75

 

 

 

85

 

 

 

95

 

 

 

105

 

 

115

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Entering Indoor Wet

 

Bulb Temperature

 

 

 

 

 

 

 

 

 

 

 

 

IDB*

 

Airflow

 

59

 

63

 

67

71

59

63

 

67

71

59

63

 

67

71

 

59

63

 

67

71

59

63

67

71

59

63

67

71

 

 

 

 

 

MBh

24.0

 

24.5

 

26.2

28.0

23.4

23.9

 

25.6

27.3

22.9

23.4

 

25.0

26.7

 

22.3

22.8

 

24.4

26.0

21.2

21.7

23.1

24.7

19.6

20.1

21.4

22.9

 

 

 

 

 

S/T

1.00

 

1.00

1.00

1.00

1.00

1.00

1.00

1.00

1.00

1.00

1.00

1.00

 

1.00

1.00

 

1.00

1.00

1.00

1.00

1.00

1.00

1.00

1.00

1.00

1.00

 

 

 

 

 

Delta T

23

 

24

25

27

23

23

25

26

22

23

24

26

 

22

22

 

24

25

21

21

22

24

19

19

21

22

 

 

 

 

950

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KW

1.66

 

1.69

1.74

1.80

1.78

1.82

1.87

1.93

1.89

1.93

1.99

2.05

 

1.98

2.03

 

2.09

2.16

2.06

2.11

2.18

2.25

2.13

2.18

2.25

2.32

 

 

 

 

 

AMPS

7.2

 

7.3

7.5

7.8

7.7

7.8

8.0

8.3

8.2

8.4

8.6

8.9

 

8.7

8.9

 

9.2

9.5

9.2

9.4

9.7

10.0

9.7

9.9

10.2

10.5

 

 

 

 

 

HI PR

222

 

239

252

263

249

268

283

295

283

305

322

336

 

323

347

 

367

382

363

391

412

430

401

431

456

475

 

 

 

 

 

LO PR

112

 

119

130

139

118

126

137

146

123

131

143

152

 

129

137

 

150

160

135

144

157

167

140

149

163

173

 

 

 

 

 

MBh

23.6

 

24.1

25.8

27.6

23.1

23.6

25.2

26.9

22.5

23.0

24.6

26.3

 

22.0

22.5

 

24.0

25.7

20.9

21.3

22.8

24.4

19.3

19.8

21.1

22.6

 

 

 

 

 

S/T

1.00

 

1.00

1.00

1.00

1.00

1.00

1.00

1.00

1.00

1.00

1.00

1.00

 

1.00

1.00

 

1.00

1.00

1.00

1.00

1.00

1.00

1.00

1.00

1.00

1.00

 

 

80

 

850

Delta T

26

 

26

28

30

25

26

27

29

24

25

27

28

 

24

24

 

26

28

23

23

25

26

21

21

23

24

 

 

 

KW

1.65

 

1.68

1.73

1.79

1.77

1.81

1.86

1.92

1.88

1.92

1.98

2.04

 

1.97

2.01

 

2.08

2.15

2.05

2.10

2.16

2.23

2.12

2.17

2.24

2.31

 

 

 

 

 

AMPS

7.2

 

7.3

7.5

7.7

7.6

7.8

8.0

8.3

8.2

8.4

8.6

8.9

 

8.7

8.8

 

9.1

9.4

9.1

9.3

9.6

9.9

9.6

9.8

10.1

10.4

 

 

 

 

 

HI PR

220

 

237

250

261

247

266

281

293

281

303

320

333

 

320

345

 

364

380

360

388

410

427

398

428

452

472

 

 

 

 

 

LO PR

111

 

118

129

138

118

125

136

145

122

130

142

151

 

128

136

 

149

159

134

143

156

166

139

148

162

172

 

 

 

 

 

MBh

22.5

 

22.9

24.5

26.2

21.9

22.4

23.9

25.6

21.4

21.9

23.4

25.0

 

20.9

21.3

 

22.8

24.4

19.8

20.3

21.7

23.2

18.4

18.8

20.1

21.4

 

 

 

 

 

S/T

1.00

 

1.00

1.00

1.00

1.00

1.00

1.00

1.00

1.00

1.00

1.00

1.00

 

1.00

1.00

 

1.00

1.00

1.00

1.00

1.00

1.00

1.00

1.00

1.00

1.00

 

 

 

 

750

Delta T

28

 

28

30

32

27

27

29

31

26

27

29

31

 

26

26

 

28

30

24

25

27

28

23

23

25

26

 

 

 

 

KW

1.63

 

1.66

1.71

1.76

1.74

1.78

1.83

1.89

1.85

1.89

1.95

2.01

 

1.94

1.98

 

2.04

2.11

2.02

2.06

2.13

2.20

2.09

2.13

2.20

2.27

 

 

 

 

 

AMPS

7.0

 

7.2

7.4

7.6

7.5

7.7

7.9

8.1

8.1

8.2

8.5

8.7

 

8.5

8.7

 

9.0

9.2

9.0

9.2

9.5

9.8

9.5

9.7

9.9

10.3

 

 

 

 

 

HI PR

216

 

232

245

256

242

261

275

287

276

297

313

327

 

314

338

 

357

372

353

380

401

419

390

420

443

462

 

 

 

 

 

LO PR

109

 

116

127

135

115

123

134

142

120

127

139

148

 

126

134

 

146

156

132

140

153

163

136

145

158

169

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: Shaded area

 

reflects ARI rating conditions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MBh

24.4

 

24.9

26.1

27.8

23.8

24.3

25.5

27.2

23.3

23.7

24.8

26.5

 

22.7

23.1

 

24.2

25.9

21.6

22.0

23.0

24.6

20.0

20.4

21.3

22.8

 

 

 

 

 

S/T

1.00

 

1.00

1.00

1.00

1.00

1.00

1.00

1.00

1.00

1.00

1.00

1.00

 

1.00

1.00

 

1.00

1.00

1.00

1.00

1.00

1.00

1.00

1.00

1.00

1.00

 

 

 

 

950

Delta T

24

 

24

25

27

23

24

25

26

23

23

24

26

 

22

22

 

23

25

21

21

22

24

19

20

21

22

 

 

 

 

KW

1.67

 

1.71

1.76

1.81

1.79

1.83

1.89

1.95

1.90

1.94

2.00

2.07

 

2.00

2.04

 

2.11

2.17

2.08

2.13

2.19

2.27

2.15

2.20

2.27

2.34

 

 

 

 

 

AMPS

7.2

 

7.4

7.6

7.8

7.7

7.9

8.1

8.4

8.3

8.5

8.7

9.0

 

8.8

9.0

 

9.2

9.5

9.3

9.5

9.7

10.1

9.7

10.0

10.3

10.6

 

 

 

 

 

HI PR

224

 

241

255

266

252

271

286

298

286

308

325

339

 

326

351

 

370

386

367

394

416

434

405

436

460

480

 

 

 

 

 

LO PR

113

 

120

131

140

120

127

139

148

124

132

144

154

 

130

139

 

152

161

137

145

159

169

141

150

164

175

 

 

 

 

 

MBh

24.0

 

24.5

25.7

27.4

23.5

23.9

25.1

26.8

22.9

23.4

24.5

26.1

 

22.4

22.8

 

23.9

25.5

21.2

21.7

22.7

24.2

19.7

20.1

21.0

22.4

 

 

 

 

 

S/T

1.00

 

1.00

1.00

1.00

1.00

1.00

1.00

1.00

1.00

1.00

1.00

1.00

 

1.00

1.00

 

1.00

1.00

1.00

1.00

1.00

1.00

1.00

1.00

1.00

1.00

 

 

85

 

850

Delta T

26

 

27

28

30

25

26

27

29

25

25

26

28

 

24

25

 

26

28

23

23

25

26

21

22

23

24

 

 

 

KW

1.66

 

1.70

1.75

1.80

1.79

1.82

1.88

1.94

1.89

1.93

1.99

2.06

 

1.99

2.03

 

2.09

2.16

2.07

2.11

2.18

2.25

2.14

2.19

2.26

2.33

 

 

 

 

 

AMPS

7.2

 

7.4

7.6

7.8

7.7

7.8

8.1

8.3

8.3

8.4

8.7

8.9

 

8.7

8.9

 

9.2

9.5

9.2

9.4

9.7

10.0

9.7

9.9

10.2

10.5

 

 

 

 

 

HI PR

223

 

240

253

264

250

269

284

296

284

306

323

337

 

324

348

 

368

383

364

392

414

431

402

433

457

477

 

 

 

 

 

LO PR

112

 

120

130

139

119

126

138

147

123

131

143

153

 

130

138

 

150

160

136

144

158

168

140

149

163

174

 

 

 

 

 

MBh

22.8

 

23.3

24.4

26.0

22.3

22.7

23.8

25.4

21.8

22.2

23.3

24.8

 

21.2

21.7

 

22.7

24.2

20.2

20.6

21.6

23.0

18.7

19.1

20.0

21.3

 

 

 

 

 

S/T

1.00

 

1.00

1.00

1.00

1.00

1.00

1.00

1.00

1.00

1.00

1.00

1.00

 

1.00

1.00

 

1.00

1.00

1.00

1.00

1.00

1.00

1.00

1.00

1.00

1.00

 

 

 

 

750

Delta T

28

 

29

30

32

27

28

29

31

27

27

29

30

 

26

27

 

28

30

25

25

26

28

23

23

24

26

 

 

 

 

KW

1.64

 

1.67

1.72

1.77

1.76

1.79

1.85

1.91

1.86

1.90

1.96

2.02

 

1.96

2.00

 

2.06

2.13

2.04

2.08

2.15

2.22

2.10

2.15

2.22

2.29

 

 

 

 

 

AMPS

7.1

 

7.2

7.4

7.7

7.6

7.7

7.9

8.2

8.1

8.3

8.5

8.8

 

8.6

8.8

 

9.0

9.3

9.1

9.3

9.5

9.8

9.5

9.7

10.0

10.4

 

 

 

 

 

HI PR

218

 

235

248

259

245

263

278

290

278

300

316

330

 

317

341

 

360

376

357

384

405

423

394

424

448

467

 

 

 

 

 

LO PR

110

 

117

128

136

116

124

135

144

121

129

140

150

 

127

135

 

147

157

133

142

155

165

138

146

160

170

 

 

 

*

NOTE:

Shaded areas

is AHRI Rating Conditions

 

IDB: Entering Indoor

Dry Bulb Temperature

 

 

KW = Total system power

 

 

 

 

 

 

 

 

 

 

 

 

 

High and low pressures are measured at the liquid and suction access fittings.

 

 

 

 

AMPS: Unit amps (comp.+ evaporator + condenser fan motors)

 

 

 

 

 

 

COOLING PERFORMANCE DATA 5MM COILS GPC1324H41AB

Page 34
Image 34
Goodmans GPC 13 SEER R-410A COOLING PERFORMANCE DATA 5MM COILS GPC1324H41AB, Expanded Performance Data, MODEL GPC1324H41A

FAQ

What data is included in the cooling performance table?

The table includes data on outdoor ambient temperature, airflow, MBh, and more.

Where can I find performance data for the Goodmans GPC1324H41A air conditioner?

You can find performance data in the official manual for the Goodmans GPC1324H41A air conditioner.

How do I interpret the data in the cooling performance table?

The data in the table provides information on the air conditioner's performance under various ambient temperatures and airflow conditions.