Goodmans GPC 13 SEER R-410A, GPC1324H41A GPC1324-42H41ABGPC1349H41AA, Wiring Diagrams, 5MM COILS

Models: GPC1324H41A GPC 13 SEER R-410A

1 47
Download 47 pages 14.36 Kb
Page 46
Image 46
5MM COILS

WIRING DIAGRAMS

5MM COILS

GPC13[24-42]H41AB GPC1349H41AA

VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

 

 

 

 

 

BK

 

 

PU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BK

 

NOTE #4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RD

 

 

1

2

3

PU

 

 

 

 

BL

 

PU

 

 

 

 

 

GR

 

RD

C

208

240

 

 

 

 

 

BK

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

G EBTDR

 

 

 

 

 

 

 

BL

 

 

 

 

 

 

 

 

 

BL

 

BK

 

 

 

24V

 

 

 

 

RD

RD

T2

L2

 

0

 

R

 

NO

 

 

 

 

 

 

 

 

 

 

 

 

8

 

K1

 

 

 

 

 

 

 

 

 

 

 

C

SEE NOTE #6

 

 

 

 

 

 

 

 

BL

 

 

 

 

 

 

 

 

-

 

 

XFMR-R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

XFMR-C

K1

COM

RD

 

 

 

 

 

 

 

RD

 

BK

T1

L1

 

2

 

 

C

 

 

 

 

 

 

 

 

 

 

 

 

BK

 

 

 

4

 

 

 

NC

 

 

 

 

 

 

 

 

 

 

 

 

 

RD RD

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SPEED

M1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

/

 

 

UP

M2

 

 

 

 

 

 

 

 

 

BK

BK

 

YL

RD

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GND

/

 

 

 

 

 

PU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60

 

 

PU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RD

 

 

 

 

 

 

 

 

 

BL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PU

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BK

BR

4

 

RD

YL

 

 

BR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LVJB

 

 

 

 

 

 

BK

 

 

 

 

 

 

 

 

 

 

 

 

 

T

 

RD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YL

Y

H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BL

 

 

 

 

 

 

E

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RD

R

 

 

 

 

 

 

 

 

 

 

 

3 PLF 6

 

 

 

 

 

GR

G

R

 

 

 

 

 

YL

H

C

 

F

 

9

 

 

 

 

WH

W1

M

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

O

 

 

 

 

 

 

 

 

 

 

 

2

5

8

BR

 

 

 

BR

W2

S

 

 

 

 

 

 

 

 

 

RCCF

 

 

 

 

T

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BL

C

 

 

 

 

 

 

 

 

 

 

 

1

4

7

 

 

 

 

A

 

 

SA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+

T

 

 

(IF USED)

 

 

RD

 

 

 

 

 

 

 

 

BR

 

 

 

 

 

 

 

SEE NOTE 5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PU

 

 

 

 

 

 

 

PU

BK

 

 

 

 

+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BK

RD

 

 

(TRANS240V)

 

 

 

 

 

 

BK

RD

 

 

 

 

 

 

 

PU

(M1) RD

 

LOW

 

 

 

YL

 

 

CONTROL

 

 

 

 

 

 

 

 

 

 

 

 

 

PU

BK

 

 

 

PU

BL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BOX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(COM)

HIGH

 

 

 

BR

 

S

C R

 

 

 

 

 

EM

 

 

 

 

 

 

 

 

 

 

 

BR

 

 

 

 

BK

BR

 

EM

 

 

 

 

 

 

RD

 

 

 

3 SPEED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BR

OPTIONAL

 

 

CM

 

 

 

RD CH

 

 

 

 

 

 

 

 

 

 

 

 

 

2 SPEED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COMP

NOTE #3

 

 

 

FC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HIGH WARNING UNIT. DO

L1

 

 

 

 

 

L2

 

 

SUPPLY VOLTAGE

 

 

208-240/1/60

 

 

 

 

CH

SEE NOTE #3

C

 

R

 

 

T2

C

T1

 

 

 

 

 

C

COMP

 

 

C

 

 

 

S

H

RCCF

 

 

 

 

 

 

F

 

 

 

S.A.

NOTE #5

CM

BR

 

 

1

P

 

 

 

 

 

 

 

1

3

 

3

L

 

 

 

F

 

 

2

4

 

 

 

 

 

M1

NOTE#2

EB TDR

 

E BTD R

 

 

 

M2

 

COM

 

 

NO

 

 

EM

 

 

 

 

 

 

 

 

 

 

 

FC

 

 

 

 

 

 

 

208-240

 

 

 

NOTE #4

 

 

2

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TR

EBTDR 24V

R G C

C

4

P

LF 5

6

R W2 W1 Y G C

THERMOSTAT

COMPONENT

 

 

 

 

 

LEGEND

 

 

 

FACTORY WIRING

BR

BLOWER INTERLOCK RELAY

 

 

 

LINE VOLTAGE

 

 

 

 

 

 

LOW VOLTAGE

C

CONTACTOR

 

 

 

 

 

 

CH

CRANKCASE HEATER

 

 

 

OPTIONAL HIGH

CM

CONDENSER MOTOR

 

 

 

VOLTAGE

COMP

COMPRESSOR

 

 

FIELD WIRING

EBTD

ELECTRONIC BLOWER TIME DELAY

 

 

 

 

 

HIGH VOLTAGE

R

RELAY

 

 

 

 

 

 

 

 

 

LOW VOLTAGE

EM

EVAPORATOR MOTOR

 

 

 

 

 

 

 

 

 

 

 

FC

FAN CAPACITOR

 

 

 

 

 

GND

EQUIPMENT GROUND

 

 

 

 

 

LVJB

LOW VOLTAGE JUNCTION BOX

 

 

 

 

 

PLF

FEMALE PLUG / CONNECTOR

 

 

 

 

 

RCCF

RUN CAPACITOR FOR

 

 

 

WIRE CODE

 

COMPRESSOR AND FAN

 

 

 

SA

 

BK

BLACK

START ASSIST

 

 

BL

BLUE

TR

TRANSFORMER

 

 

BR

BROWN

 

 

 

 

 

 

GR

GREEN

 

 

 

OR

ORANGE

 

 

 

PU

PURPLE

 

 

 

RD

RED

 

 

 

WH

WHITE

 

 

 

YL

YELLOW

NOTES:

1.REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS ORIGINAL (AT

LEAST 105°C) USE COPPER CONDUCTOR ONLY.

2.TO CHANGE EVAPORATOR MOTOR SPEED REPLACE LEAD ON EBTDR "COM" WITH LEAD

ON EBTDR "M1" OR "M2"

3.CRANKCASE HEAT NOT SUPPLIED ON ALL UNITS.

4.FOR 208 VOLT TRANSFORMER OPERATION MOVE PURPLE WIRES FROM TERMINAL 3

TERMINAL 2 ON TRANSFORMER.

5.START ASSIST FACTOR EQUIPPED WHEN REQUIRED

6.USE COPPER CONDUCTORS ONLY

++ USE N.E.C. CLASS 2 WIRE

SEE UNIT RATING PLATE FOR TYPE AND SIZE

OF OVER CURRENT PROTECTION

208-240/1/60 0140G00364 REV. A

Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.

46

Page 46
Image 46
Goodmans GPC 13 SEER R-410A, GPC1324H41A GPC1324-42H41ABGPC1349H41AA, Wiring Diagrams, 5MM COILS, High Warning Unit. Do

FAQ

What precautions should be taken before servicing or installing the air conditioner?

You should disconnect all power sources to avoid property damage, personal injury, or death.

What should be done if multiple power sources may be present?

You should still disconnect all power sources to avoid property damage, personal injury, or death.

What types of conductors should be used for the wiring?

You should use copper conductors with at least 105C insulation.