PRODUCT DESIGN

PRODUCT DESIGN

GPC Package Cooling Units are designed for outdoor instal- lations only in either residential or light commercial applica- tions.

The connecting ductwork (Supply and Return) can be con- nected for either horizontal or vertical airflow. In the vertical application a matching Roof Curb is recommended.

Location and Clearances

NOTE: To ensure proper condensate drainage, unit must be installed in a level position.

A return air filter must be installed behind the return air grille(s) or provision must be made for a filter in an accessible loca- tion within the return air duct. The minimum filter area should not be less than those sizes listed in the Specification Sec- tion. Under no circumstances should the unit be operated without return air filters.

A 3/4” PVC pipe is provided for removal of condensate water from the indoor coil In order to provide proper condensate flow, a drain trap is supplied and shipped loose inside the unit for field installation. (Do not reduce the drain line size.)

Refrigerant flow control is achieved by use of restrictor ori- fices. GPC units use the FasTest Access Fitting System with a saddle that is either soldered to the suction and liquid lines or is fastened with a locking nut to the access fitting box (core) and then screwed into the saddle. Do not re- move the core from the saddle until the refrigerant charge has been removed. Failure to do so could re- sult in property damage or personal injury.

36"

UNIT

36"

Location and Clearances10" Outside Slab Installation - Horizontal (H)

WALL

36"

The single phase units use permanent split capacitor (PSC) design compressors. Starting components are therefore not required for these units. A low microfarad run capacitor as- sists the compressor to start and remains in the circuit dur- ing operation.

Outside Slab Installation - Horizontal (H)

Minimum clearances are required to avoid air recirculation and keep the unit operating at peak efficiency.

The outdoor fan and indoor blower motors are single phase capacitor type motors with the exception of the GPC1360H41* units which have X-13 indoor blower motors that are ener- gized by a 24V signal from the thermostat and are constant torque motors with very low power consumption. The X-13 features an integral control module.

Air for condensing (cooling cycle) is drawn through the out- door coil by a propeller fan, and is discharged vertically out the top of the unit. The outdoor coil is designed for .0 static. No additional restriction (ductwork) shall be applied.

Conditioned air is drawn through the filter(s), field installed, across the coil and back into the conditioned space by the indoor blower.

GPC1324-30H41* use Copeland Reciprocating Compressors.

- Due to their design Scroll Compressors are inherently

more tolerant of liquid refrigerant. NOTE: Even though the

compressor section of a Scroll compressor is more toler-

ant of liquid refrigerant, continued floodback or flooded

start conditions may wash oil from the bearing surfaces

36"

PL Rooftop Installation - Horizontal (H)Manual background ENUMManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

UNI

T

24"

P

 

 

 

B

 

 

 

R

L

 

 

U

 

A

 

C

 

 

T

 

 

 

 

F

 

 

 

 

O

 

 

 

 

R

 

 

 

 

M

 

36"

causing premature bearing failure.

- Scroll Compressors use white oil which is compatible

with 3GS oil which may be used if additional oil is re-

quired.

- Operating pressures and amp draws may differ from stan-

dard reciprocating compressors. This information may be

found in the "Cooling Performance Data" section.

Rooftop Installation - Horizontal (H)

4

Page 4
Image 4
Goodmans GPC 13 SEER R-410A Product Design, Outside Slab Installation - Horizontal H, Rooftop Installation - Horizontal H

FAQ

What type of air conditioning units are GPC Package Cooling Units?

GPC Package Cooling Units are designed for outdoor installations in residential or light commercial applications.

What are the minimum clearances required for outside slab installation?

Minimum clearances are required to avoid air recirculation and keep the unit operating at peak efficiency.

What type of compressors are used in GPC1324-30H41* units?

GPC1324-30H41* units use Copeland Reciprocating Compressors.