11 Gas Information

11 Gas Information

A. Gas Pressure Requirements

B. Gas Connection

Pressure requirements for XLR-CE fireplaces are shown in Table 11.1 below.

Two taps are provided on the right hand side of the gas control for a test gauge connection to measure the inlet and outlet pressures.

The fireplace and its individual shut-off valve must be dis- connected from the gas supply piping system during any pressure testing of the system at test pressures in excess of 60 mbar.

If the fireplace must be isolated from the gas supply pip- ing system by closing an individual shut-off valve, it must be of the handle-less type.

A. Gas Pressure Requirements WARNING

Fire Risk

Explosion Risk

High pressure will damage valve.

Disconnect gas supply piping BEFORE pressure testing gas line at test pressures above 60 mbar.

Close the manual shutoff valve BEFORE pressure testing gas line at test pressures equal to or less than 60 mbar.

 

ON/OFF/REMOTE

GAS VALVE

SWITCH

 

CONTROL

DC ADAPTER

BATTERY

MODULE

PACK

Figure 11.1. Valve Components

Note: Have the gas supply line installed in accordance with local building codes by a qualified installer approved and/or licensed as required by the locality.

Note: Before the first firing of the appliance, the gas supply line should be purged of any trapped air.

Note: Consult local building regulations to properly size the gas supply line leading to the (Rp 1/2 in.) hook-up at the unit.

Incoming gas line should be piped into the valve compart- ment and connected to the ISO 7-Rp 1/2 (BSP Rp 1/2) threaded gas inlet connection on the manual shutoff valve.

Leak test all gas line points and the gas control valve prior to and after starting the gas appliance.

B. Gas Connection WARNING

CHECK FOR GAS LEAKS

Explosion Risk

Fire Risk

Asphyxiation Risk

Check all fittings and connections.

Do not use open flame.

After the gas line installation is complete, all connections must be tightened and checked for leaks with a commercially-available, non- corrosive leak check solution. Be sure to rinse off all leak check solution following testing.

Fittings and connections may have loosened during shipping and handling.

C. Access Through the Valve Assembly

Refer to Section 16.C.

 

Natural Gas

Propane

Propane

Butane

Butane

Natural Gas

 

(G20)

(G31)

(G31)

(G30)

(G30)

(G25)

CAT

I2H, I2E, I2E+

I3P

 

I3P

 

I3B/P

 

I3B/P

 

I2E+

 

Inlet Pressure

20 mbar

37 mbar

50 mbar

30 mbar

50 mbar

25 mbar

Burner Pressure

8.7 mbar

25 mbar

25 mbar

25 mbar

25 mbar

8.7 mbar

Gas Rate

.405 m3/

h

.134 m3/

h

.134 m3/

h

.111 m3/

h

.111 m3/

h

.40 m3/

h

Heat Input (Net)

7.32 kW

6.74 kW

6.74 kW

6.44 kW

6.44 kW

7.32 kW

 

 

 

 

 

 

 

Burner Injector

DMS 42

DMS .057

DMS .057

DMS 55

DMS 55

DMS 42

 

 

 

 

 

 

 

 

 

 

 

 

 

Pilot Injector

51

 

30

 

30

 

30

 

30

 

51

 

Columns highlighted in gray = The gas control valve supplied with this product is approved for a maximum inlet pressure of 37 mbar. For pressures over 37 mbar, an in line pressure regulator must be installed upstream from the gas control valve.

Heat & Glo • XLR-N-CE, XLR-PB-CE2198-900 Rev. J • 5/12