Non-Combustible Finish Materials

0 cm to 10,16 cm Thick Inside Fit Method

The Tonic decorative front is approved for inside fit appli- cations. Non-combustible finishing materials up to 10,16 cm thick can be installed around the front (left, right, top, and bottom).

For the Tonic decorative front inside fit applications, the decorative front must be installed tight to the finishing flanges and must not overlap any finish material.

Ensure that no non-combustible finish materials are in- stalled within 1,9 cm of the fireplace opening. The 1,9 cm spacing is required to provide clearance for removing and installing the Tonic decorative front. See Figure 13.9.

FACTORY-INSTALLED

NON-COMBUSTIBLE

BOARD

0-10 cm

1,9 cm

52 cm APPLIANCE OPENING (HEIGHT)

4,6 cm

0-10 cm

DRYWALL OR EQUIVALENT (1,3 cm)

Figure 13.8 Inside Fit Method (Tonic Decorative Front Only)

Non-Combustible Finish Material 0-10 cm Thick

1,9 cm

1,9 cm

 

4,6 cm

 

Bottom Joint

Figure 13.9 Noncombustible Surface Finishing Material 0 - 10

cm Thick-Inside Fit Method (Tonic Decorative Front

Only)

48

Heat & Glo • XLR-N-CE, XLR-PB-CE2198-900 Rev. J • 5/12

Page 48