Heat & Glo LifeStyle XLR-PB-CE Listing and Code Approvals, A. Appliance Certification, Propane

Models: XLR-N-CE XLR-PB-CE

1 65
Download 65 pages 6.02 Kb
Page 7
Image 7
1 Listing and Code Approvals

1 Listing and Code Approvals

A. Appliance Certification

MODELS: XLR-N-CE, XLR-PB-CE

LABORATORY: GL Industries Ltd.

TYPE: Gas Fireplace

STANDARD: Latest version of BS EN 613: 2001

DIRECTIVE: GAD90/396/EEC

A. Additional Related Standards

The installation must comply with these installation instruc- tions and all relevant parts of Local and National Building Standards Regulations and those relevant recommenda- tions of the following British Standards. BS 5871: Part 1 BS 8303 BS 5440: Parts 1 & 2 BS 6891 BSEN1856 Parts 1 & 2 BS 5482 Part 1, as well as IGE/UP/7.

NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.

This appliance is tested and approved as either supplemen- tal room heat or as a decorative appliance. It should not be factored as primary heat in residential heating calculations.

The Heat & Glo gas appliances discussed in this Installer’s Guide have been tested to certification standards and listed by the applicable laboratories.

This appliance must be installed in accordance with the rules in force.

NOX Class 5 for G20, NOX Class 5 for G31

The fireplace and its individual shut-off valve must be dis- connected from the gas supply piping system during any pressure testing of the system at test pressures in excess of 60 mbar.

If the fireplace must be isolated from the gas supply pip- ing system by closing an individual shut-off valve, it must be of the handle-less type.

C. Non-Combustible Materials Specification

Material which will not ignite and burn. Such materials are those consisting entirely of steel, iron, brick, tile, concrete, slate, glass or plasters, or any combination thereof.

Materials that are reported as passing ASTM E 136,

Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750 ºC and UL763 shall be considered non-combustible materials.

D. Combustible Materials Specification

Materials made of or surfaced with wood, compressed pa- per, plant fibers, plastics, or other material that can ignite and burn, whether flame proofed or not, or plastered or unplastered shall be considered combustible materials.

E. Electrical Codes

All electrical safety testing has been done following the EN 60335-2-102 standard. Local codes apply.

B. Gas Pressure Requirements

Pressure requirements for XLR fireplaces are shown in table below.

Two taps are provided on the right hand side of the gas control for a test gauge connection to measure the inlet and outlet pressures.

 

Natural Gas

Propane

Propane

Butane

Butane

Natural Gas

 

(G20)

(G31)

(G31)

(G30)

(G30)

(G25)

CAT

I2H, I2E, I2E+

I3P

 

I3P

 

I3B/P

 

I3B/P

 

I2E+

 

Inlet Pressure

20 mbar

37 mbar

50 mbar

30 mbar

50 mbar

25 mbar

Burner Pressure

8.7 mbar

25 mbar

25 mbar

25 mbar

25 mbar

8.7 mbar

Gas Rate

.405 m3/

h

.134 m3/

h

.134 m3/

h

.111 m3/

h

.111 m3/

h

.40 m3/

h

Heat Input (Net)

7.32 kW

6.74 kW

6.74 kW

6.44 kW

6.44 kW

7.32 kW

 

 

 

 

 

 

 

Burner Injector

DMS 42

DMS .057

DMS .057

DMS 55

DMS 55

DMS 42

 

 

 

 

 

 

 

 

 

 

 

 

 

Pilot Injector

51

 

30

 

30

 

30

 

30

 

51

 

Columns highlighted in gray = The gas control valve supplied with this product is approved for a maximum inlet pressure of 37 mbar. For pressures over 37 mbar, an in line pressure regulator must be installed upstream from the gas control valve.

Heat & Glo • XLR-N-CE, XLR-PB-CE2198-900 Rev. J • 5/12

7

Page 7
Image 7
Heat & Glo LifeStyle XLR-PB-CE Listing and Code Approvals, A. Appliance Certification, A. Additional Related Standards