WARNING

Fire Risk. Explosion Risk.

Do NOT pack insulation or other combustibles between ceiling firestops.

ALWAYS maintain specified clearances around venting and firestop systems.

Install wall shield and ceiling firestops as specified.

Failure to keep insulation or other material away from vent pipe may cause fire.

Top Vent - Horizontal Termination

Venting with 1 elbow

V Minimum

H1 Maximum

90 Elbow

61,0 cm

 

 

30,5 cm

91,4 cm

 

 

61,0 cm

1,5 m

 

 

91,4 cm

2,1 m

 

 

120 cm

4,3 m

 

 

H Max. =4,3 m

V + H Max. = 12,2 m

Note: Use SLP Series components only.

H1

V1

Figure 7.3

24

Heat & Glo • XLR-N-CE, XLR-PB-CE2198-900 Rev. J • 5/12

Page 24
Image 24