IntelliFire Plus™ Ignition System - (continued)
Symptom | Possible Cause | Corrective Action |
|
|
|
|
|
| a. A shorted or loose connection in flame | Verify all connections to wiring diagram in manual. Verify |
|
4. Pilot lights but contin- | sensing rod. | connections underneath pilot assembly are tight. Verify con- |
|
ues to spark, and main |
| nections are not grounding out to metal chassis, pilot burn- |
|
burner will not ignite. |
| er, pilot enclosure or screen if present, or any other metal |
|
(If the pilot continues |
| object. |
|
to spark after the |
|
|
|
b. Poor flame rectification or contaminated | With fixed glass assembly in place, verify that flame is en- |
| |
pilot flame has been lit, |
| ||
flame sensing rod. | gulfing flame sensing rod on left side of pilot hood. Flame |
| |
flame rectification has |
| ||
| sensing rod should glow shortly after ignition. Verify cor- |
| |
not occurred.) |
|
| |
| rect pilot orifice is installed and gas inlet is set to pressure |
| |
|
|
| |
|
| specifications. Polish flame sensing rod with fine steel wool | |
|
| to remove any contaminants that may have accumulated on |
|
|
| flame sensing rod. |
|
|
|
|
|
| c. Module is not grounded. | Verify module is securely grounded to metal chassis of ap- |
|
|
| pliance. Verify that wire harness is firmly connected to the |
|
|
| module. |
|
|
|
|
|
| d. Damaged pilot assembly or contami- | Verify that ceramic insulator around the flame sensing rod |
|
| nated flame sensing rod. | is not cracked, damaged, or loose. Verify connection from |
|
|
| flame sensing rod to white sensor wire. Polish flame sens- | |
|
| ing rod with fine steel wool to remove any contaminants |
|
|
| that may have accumulated on flame sensing rod. Verify |
|
|
| continuity with a multimeter with ohms set at lowest range. |
|
|
| Replace pilot if any damage is detected. |
|
|
|
|
|
| e. Module. | Turn ON/OFF rocker switch or wall switch to OFF position. |
|
|
| Remove ignitor wire “I” from module. Place ON/OFF rocker |
|
|
| switch or wall switch in ON position. If there is no spark at “I” |
|
|
| terminal module must be replaced. If there is a spark at “I” |
|
|
| terminal, module is fine. |
|
|
|
|
|
Heat & Glo • | 53 |