I. Control Module Operation
1.The control module has an ON/OFF/REMOTE selector switch that must be set. See Figure 2.3.
OFF Position: Appliance will ignore all power inputs and will not respond to any commands from a wall switch or optional remote. The unit should be in the OFF position during installation, service, battery installation, , fuel conversion, and in the event that the control goes into
ON Position: Appliance will ignite and run continuously in the HI flame setting, with no adjustment in flame output. This mode of operation is primarily used for initial installation or power outage operation with battery backup.
REMOTE Position: Appliance will initiate commands from a wired wall switch and/or one of the optional wireless remote options.
2.A wall switch can be wired into the control module brown and red wires. See Figure 12.1.
3.The control module has safety feature that automatically shuts down the fireplace after 9 hours of continuous operation without receiving a command from the wall switch or optional remote.
4.If you intend to use both a wired wall switch and an optional remote control to operate your fireplace, the wall switch will override any commands given by the remote.
| MODULE |
|
| SELECTOR | |
| SWITCH | |
FLAME HI/LOW | STATUS | NG/LP |
SWITCH | INDICATOR LED | SELECTOR SWITCH |
Figure 2.3 Control Module
Note: The HI/LO and LP/NG switches on the control module are
Nine Hour Safety Shutdown Feature
This appliance has a safety feature that automatically shuts down the fireplace after nine hours of continuous operation with receiving a command from the wall switch or optional remote.
5.Module Reset Switch
This module may |
|
When this occurs, the appliance will not ignite or |
|
respond to commands. The module will go into |
|
mode by emitting three audible beeps, then continuously | |
displaying an error code at its status indicator LED. |
•Check battery tray. Remove batteries if installed. Batteries should only be installed for use during power outages. See Section H.
•Locate the module reset switch. See Figure 2.4 or 2.5.
•Set the module reset switch to the RESET position.
•Wait five (5) minutes to allow possible accumulated gas to clear.
•Set the module reset switch to ON.
•Start the appliance.
WARNING! Risk of Explosion! DO NOT press the mod- ule reset switch more than one time within a five minute time period. Gas may accumulate in firebox. Call a quali- fied service technician.
MODULE RESET |
SWITCH |
Figure 2.4 Location of Module Reset Switch - Tonic Front
MODULE RESET |
SWITCH |
Figure 2.5 Location of Module Reset Switch - Martini Front
10 | Heat & Glo • |