B. Mantel and Wall Projections
WARNING! Risk of Fire! Comply with all minimum clear- ances to combustibles as specified. Framing closer than the minimums listed must be constructed entirely of noncom- bustible materials (i.e., steel studs, concrete board, etc.) Failure to comply could cause fire.
Mantels (Combustible/Non-Combustible)
1,3 cm Thick Wall
Sheathing 30 cm
MAX.
MEASUREMENT
36 cm FROM TOP OF MIN. FIREPLACE
OPENING
Figure 13.5 Clearances To Combustible Mantels Or Other
Combustibles Above Appliance
Note: For
Mantel Leg (Combustible/Non-Combustible)
TOP VIEW
8 cm
MINIMUM UNLIMITED
18 cm
Figure 13.6 Non-Combustible Mantel Leg or Wall Projections (Acceptable on both sides of opening)
C. Facing Material
•Facing and/or finishing materials must not interfere with air flow through louvers, operation of louvers or doors, or access for service.
•Facing and/or finishing materials must never overhang into the glass opening.
•Observe all clearances when applying combustible materials.
WARNING! Risk of Fire! DO NOT apply combustible materials beyond the minimum clearances. Comply with all minimum clearances to combustibles as specified in this manual. Overlapping materials could ignite and will interfere with proper operation of doors and louvers.
WARNING! Risk of Fire! DO NOT install drywall or other combustible materials over the
Decorative facing material thickness is measured from the face of the
3,8 cm ABOVE STANDOFF | |
| |
| |
| FINISHING MATERIAL |
| 0 - 2,5 cm THICK |
| TONIC DECORATIVE |
| FRONT SHOWN |
| |
| FINISHING MATERIAL |
| 0 - 2,5 cm THICK |
DRYWALL OR |
|
EQUIVALENT (1,2 cm) |
Figure 13.7 Overlap Fit Method (Tonic or Martini Decorative Front)
Both the Tonic and Martini decorative fronts can be in- stalled with an “Overlap” or “Inside Fit” method:
Overlap Requirement: See Figure 13.7.
Inside Fit requirement: See Figure 13.8 and 13.9.
0 - 2,54 cm
Both the Tonic and Martini decorative fronts are designed to overlap finish materials 0 cm to 2,54 cm thick. See Figure 13.6.
NOTICE: This 2.54 cm maximum not only includes the decorative finish materials (marble, tile, slate, etc) but also the mortar or adhesive used to attach the decorative finish material.
The
Heat & Glo • | 47 |