Heat & Glo LifeStyle XLR-PB-CE Termination Locations, A. Vent Termination Minimum Clearances

Models: XLR-N-CE XLR-PB-CE

1 65
Download 65 pages 6.02 Kb
Page 21
Image 21
6 Termination Locations

6 Termination Locations

A. Vent Termination Minimum Clearances

A. Vent Termination Minimum Clearances WARNING

Fire Risk.

Maintain vent clearance to combustibles as specified.

DO NOT pack air space with insulation or other materials.

Failure to keep insulation or other materials away from vent pipe may cause overheating and fire.

 

A

B

 

 

15,2 cm (minimum) up to 50,8 cm

45,7 cm minimum

 

 

 

 

 

 

50,8 cm and over

0 cm minimum

 

Gas, Wood or Fuel Oil

Termination Cap

B

A*

TERMINATION

CAP

HORIZONTAL

OVERHANG

51 cm

VERTICAL

WALL

LOWEST

DISCHARGE

OPENING

X

30,5 cm

Manual background ROOF PITCH

IS X/ 30,5 cm

H (MIN.) - MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING

Gas

Termination

Cap **

*If using decorative cap cover(s), this distance may need to be increased. Refer to the installation instructions supplied with the decorative cap cover.

**In a staggered installation with both gas and wood or fuel oil terminations, the wood or fuel oil termination cap must be higher than the gas termination cap.

Figure 6.2 Staggered Termination Caps

Angle

H (Min.) cm

0°-26.6°

30*

26.6°-30.3°

38*

30.3°-33.7°

46*

33.7°-36.9°

61*

36.9°-39.8°

76.

39.8°-42.5°

99

42.5°-45.0°

122.

45.0°-49.4°

152.

49.4°-53.1°

183.

53.1°-56.3°

213.

56.3°-59.0°

229.

59.0°-60.3°

244.

*.91 M minimum in snow regions

Figure 6.1 Minimum Height From Roof To Lowest Discharge Opening

Heat & Glo • XLR-N-CE, XLR-PB-CE2198-900 Rev. J • 5/12

21

Page 21
Image 21
Heat & Glo LifeStyle XLR-PB-CE, XLR-N-CE manual Termination Locations, A. Vent Termination Minimum Clearances