Goodmans GPC1324H41A Wiring Diagrams, GPC1360H41BB, 5MM COILS, High Warning Unit. Do

Models: GPC1324H41A GPC 13 SEER R-410A

1 47
Download 47 pages 14.36 Kb
Page 47
Image 47
GPC1360H41BB

WIRING DIAGRAMS

5MM COILS

GPC1360H41BB

VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

 

 

 

PU

NOTE #3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BK

BK

 

 

 

 

 

 

 

 

 

 

 

PU

 

BL

 

PU

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

BK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BL

 

RD

T2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RD

 

C

 

 

 

 

 

BL

 

 

 

 

SEE NOTE 5

 

 

 

 

 

 

BK

T1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BK

 

 

 

 

 

 

 

 

RD

 

 

 

 

 

/

 

 

 

 

 

 

YL

 

 

/

 

 

 

 

GR

 

 

 

 

GND

BK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RD

 

 

 

 

 

 

 

 

RD

 

YL

 

 

 

 

 

 

 

 

 

 

 

 

PU

 

 

 

 

 

 

 

 

 

 

 

 

 

YL

 

 

 

 

LVJB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RD BR

WH

 

 

 

 

 

H

 

 

 

 

WH

 

GR

YL

Y

 

 

 

BL

 

 

E

 

 

 

PLF

 

 

 

RD

R

 

 

 

 

 

 

R

 

 

 

 

 

 

 

 

GR

G

 

 

YL

H C

 

 

 

 

WH

W1

M

 

 

 

 

 

 

O

BL

 

 

RCCF

 

 

 

 

 

 

 

 

BR

 

 

BR

W2

S

 

 

 

 

 

 

 

GR

 

 

 

 

 

 

 

BL

C

A

 

 

 

 

 

 

 

 

 

 

 

 

PU

BR

 

 

 

 

++

 

 

 

 

 

 

 

 

 

 

 

 

 

RD

 

 

BK

 

 

 

 

 

 

 

SA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(IF USED) SEE NOTE 4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RD

 

 

 

 

 

 

 

 

 

BK

 

 

CONTROL

 

 

 

 

PU BR

 

YL

 

 

 

YL

 

 

BK

 

 

BOX

 

 

GR

 

 

 

 

 

 

WH

 

 

 

S

C

R

 

 

C

G N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CM

 

COMP

 

 

 

 

 

 

 

 

 

 

 

 

SEE NOTE 2

EM

 

 

 

 

 

 

 

 

 

HIGH WARNING UNIT. DO

L1

 

 

 

L2

 

 

SUPPLY VOLTAGE

 

 

 

208-240/1/60

 

 

 

R

T2

C

C

T1

 

 

 

 

 

 

 

C COMP

C

 

 

 

 

 

 

 

S

H RCC F

 

 

 

 

F

 

 

 

S.A.

NOTE #4

CM

 

IF USED

 

 

 

NOTE #2

 

 

 

N

EM

 

L

 

3

 

 

 

 

 

 

1

G

2

 

 

 

 

 

 

 

 

208-240

 

 

 

NOTE #4

2

1

 

 

3

 

TR

24V

Manual backgroundManual backgroundManual background EM C

SEE NOTE #2

4

5

6

C

COMPONENT LEGEND

 

 

 

FACTORY WIRING

C

CONTACTOR

 

 

 

LINE VOLTAGE

 

 

 

LOW VOLTAGE

CM

CONDENSER MOTOR

 

 

 

 

 

 

OPTIONAL HIGH

COMP

COMPRESSOR

 

 

 

 

 

 

VOLTAGE

EM

EVAPORATOR MOTOR

 

 

 

 

 

 

 

 

GND

EQUIPMENT GROUND

 

 

 

FIELD WIRING

LVJB

LOW VOLTAGE JUNCTION BOX

 

 

 

 

 

 

HIGH VOLTAGE

PLF

FEMALE PLUG / CONNECTOR

 

 

 

 

 

 

LOW VOLTAGE

RCCF

RUN CAPACITOR FOR^J

 

 

 

 

 

 

 

 

SA

COMPRESSOR AND FAN

 

 

 

 

 

START ASSIST

 

 

 

 

 

TR

TRANSFORMER

 

 

 

 

WIRE CODE

 

 

 

 

 

 

 

 

 

 

 

BK

BLACK

 

 

 

 

 

BL

BLUE

 

 

 

 

 

BR

BROWN

 

 

 

 

 

GR

GREEN

 

 

 

 

 

OR

ORANGE

 

 

 

 

 

PU

PURPLE

 

 

 

 

 

RD

RED

 

 

 

 

 

WH

WHITE

 

 

 

 

 

YL

YELLOW

NOTES:

1.REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONLY.

2.TO CHANGE EVAPORATOR MOTOR SPEED MOVE WHITE AND YELLOW LEADS FROM EM "2" AND "3" TO "4" AND "5". IF BOTH LEADS ARE ENERGIZED, THE HIGHER SPEED SETTING IS USED.

3.FOR 208 VOLT TRANSFORMER OPERATION MOVE PURPLE WIRES FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER.

4.START ASSIST FACTORY EQUIPPED WHEN REQUIRED

5.USE COPPER CONDUCTORS ONLY.

++ USE N.E.C. CLASS 2 WIRE

SEE UNIT RATING PLATE FOR TYPE AND SIZE

OF OVER CURRENT PROTECTION

R W2 W1 Y G C

Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.

47

Page 47
Image 47
Goodmans GPC1324H41A, GPC 13 SEER R-410A service manual Wiring Diagrams, GPC1360H41BB, 5MM COILS, High Warning Unit. Do

FAQ

What precautions should I take before servicing the air conditioner?

It is important to disconnect all power sources to avoid property damage, personal injury, or death.

Can I use copper conductors for wiring?

Yes, use copper conductors only for wiring to ensure safety and compliance with regulations.

Where can I find the most up-to-date wiring diagram for the air conditioner?

Always refer to the wiring diagram on the unit for the most up-to-date wiring information.