Goodmans GPC1324H41A Blower Performance Data, GPC1324-60H41, Dry Coil Data, Model, Speed, Volts

Models: GPC1324H41A GPC 13 SEER R-410A

1 47
Download 47 pages 14.36 Kb
Page 9
Image 9

BLOWER PERFORMANCE DATA

GPC13[24-60]H41**

Dry Coil Data

Model

Speed

 

Volts

 

 

 

E.S.P (In. of H2O)

 

 

 

 

0.1

0.2

0.3

0.4

0.5

 

0.6

0.7

0.8

 

 

 

 

 

 

GPC1324H41**

Low

230

 

CFM

680

640

590

555

505

 

440

340

-

 

WATTS

155

150

145

140

130

 

120

110

-

High

230

 

 

 

 

 

 

 

 

Med

230

 

CFM

895

855

815

755

700

 

630

545

390

 

 

WATTS

230

220

215

205

195

 

180

170

145

 

 

 

 

 

 

 

 

 

CFM

1,185

1,130

1,070

1,010

930

 

850

760

650

 

 

 

 

WATTS

350

340

325

310

295

 

280

265

245

GPC1330H41**

Low

230

 

CFM

1,150

1,080

1,025

975

925

 

845

-

-

 

WATTS

340

330

315

305

295

 

280

-

-

High

230

 

WATTS

485

465

455

435

415

 

400

385

370

 

Med

230

 

CFM

1,335

1,275

1,205

1,135

1,075

 

985

910

845

 

 

WATTS

425

415

400

385

370

 

350

330

310

 

 

 

 

CFM

1,435

1,355

1,290

1,210

1,130

 

1,040

960

885

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GPC1336H41**

 

 

 

CFM

1,180

1,125

1,075

1,020

955

 

875

655

-

High

230

 

WATTS

495

480

465

440

425

 

400

385

370

 

Low

230

 

WATTS

335

325

315

305

295

 

275

240

-

 

Med

230

 

CFM

1,350

1,280

1,205

1,130

1,050

 

985

910

845

 

 

WATTS

435

420

405

385

375

 

350

330

310

 

 

 

 

CFM

1,450

1,370

1,290

1,205

1,130

 

1,040

960

885

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GPC1342H41** GPC1349H41**

 

 

 

CFM

1,425

1,410

1,355

1,310

1,245

 

1,170

1,080

-

High

230

 

WATTS

765

755

735

715

695

 

670

640

615

 

Low

230

 

WATTS

450

445

430

420

405

 

390

370

-

 

Med

230

 

CFM

1,620

1,595

1,545

1,485

1,425

 

1,345

1,250

1,160

 

 

WATTS

550

540

525

510

495

 

475

450

425

 

 

 

 

CFM

1,945

1,935

1,875

1,800

1,730

 

1,635

1,535

1,440

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GPC1348H41**

Low

230

 

CFM

1,425

1,410

1,355

1,310

1,245

 

1,170

1,080

-

 

WATTS

450

445

430

420

405

 

390

370

-

High

230

 

WATTS

785

780

765

745

720

 

705

665

625

 

Med

230

 

CFM

1,720

1,660

1,585

1,520

1,460

 

1,365

1,270

-

 

 

WATTS

560

555

540

530

520

 

490

470

-

 

 

 

 

CFM

2,110

2,060

1,980

1,895

1,795

 

1,705

1,590

1,500

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GPC1360H41**

 

 

 

CFM

1,775

1,635

1,645

1,515

1,510

 

1,450

1,430

1,400

T4/T5

230

 

WATTS

575

595

620

630

645

 

655

660

670

 

T1

230

 

WATTS

395

420

435

445

455

 

465

470

475

 

T2/T3

230

 

CFM

1,845

1,790

1,715

1,685

1,590

 

1,580

1,530

1,500

 

 

WATTS

490

505

520

535

550

 

560

570

575

 

 

 

 

CFM

2,025

1,900

1,840

1,780

1,725

 

1,650

1,620

1,580

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTES:

1.Data shown is Dry Coil. Wet Coil Pressure Drop is approximate.

2.0.1" H2O, for 2 row indoor coil; 0.2” H2O, for 3 row indoor coil; and 0.3” H2O, for 4 row indoor coil.

3.Data shown does not include filter pressure drop, approx. 0.08” H2O.

4.Reduce airflow by 2% for 208V operation.

9

Page 9
Image 9
Goodmans GPC1324H41A Blower Performance Data, GPC1324-60H41, Dry Coil Data, Model, Speed, Volts, E.S.P In. of H2O

FAQ

What data is shown in the table?

The data shown is for Dry Coil. Wet Coil Pressure Drop is approximate.

What does the ESP in.of H2O represent?

The ESP in.of H2O represents the external static pressure in inches of water.

How does the filter pressure drop impact the data?