Security Modes

When the meters were originally programmed by the system administrator, one of the following security choices was entered:

System Monitoring

PIN Code

Parts Room Authorization

Prior to dispensing, it may be necessary to complete one of the following security procedures, depending on the security mode selected.

System Monitoring

When set for system monitoring, no security authoriza- tion is required by the operator. However, any amount of fluid dispensed is automatically sent by the meter to the PC where it is recorded for future reference.

PIN Code

PIN Code (personal identification number) means that a four digit PIN code must be entered at the meter to obtain dispense authorization. To use a meter with PIN code security:

1.Use the up and down arrow keypad buttons to select the first number of the PIN code.

2.Press the right keypad button to move the cursor to the next position.

3.Use the up and down keypad buttons to select the desired number. Continue this process until the PIN code number is completed. See FIG. 12.

Meter Operation

PIN CODE

ENTER

2122

LEFTRIGHT

FIG. 12

4.When the pin code is complete, press the right key- pad button until the cursor underlines the Enter option. Press the up arrow on the meter keypad. This action will enter the PIN code and send it to the PC.

5.The PC recognizes the PIN code and authorizes the meter to dispense.

Parts Room Authorization

This mode provides high level security and requires a Parts Room Administrator to authorize each dispense.

AUTHORIZATION

REQUIRED

REQUESTREQUEST

APPROVALAPPROVAL

FIG. 13

1.Press either the left keypad or right keypad button under REQUEST APPROVAL. This sends the request to the parts room administrator’s PC for dis- pense authorization. See FIG. 13.

2.The administrator grants authorization at the PC, which then authorizes the meter to dispense.