Service

FIG. 29

FIG. 30

FIG. 31

13.Assemble the covers (18 & 19). Insert several of the screws (12) to temporarily hold the cover halves (18 & 19) together. Test the display by inserting a bat- tery (11) and powering on the unit.

If the display does not appear:

make sure that a charged battery (11) is being used.

check that the connections from the new bezel (31) to the circuit board (112) are fastened cor- rectly and securely.

check that all remaining parts are repositioned securely and in the correct location.

14.If the display appears and is operating correctly, replace the remaining screws (12) and (42) that fas- ten the cover halves (18 & 19) together. Torque all screws to 7 - 10 in. lbs.

15.Replace the rear boot (24) and impact guard (40).

16.Attach the meter to the fluid line by following steps listed on page 9.

Replacing the Trigger

Trigger Repair Kits 246439 for meter 246008 and 249883 for meter 249881 are available and can be ordered separately. See the Parts List for the 246008 and 249881 Electronic Meters on page 33. The parts with a next to their reference numbers are included in this repair kit.

The PSM switch (101) comes attached to the right meter cover half (18). Do not remove it during the meter cover repair procedure.

When repairing the meter using the Trigger Repair Kit, use all of the new parts. To replace the parts do the fol- lowing.

CAUTION

Be sure to use the disposable grounding wrist strap included with the repair kit. Static electricity can dam- age the electrical components within the meter as the repair is completed.

24

309497L

Page 24
Image 24
Graco 249881, 246008 instruction manual Replacing the Trigger