9.Pull the bezel (31) away and up from the right cover half (18). See FIG. 26.

FIG. 26

C

B

A

Service

When reconnecting cable C to the circuit board (112), ensure that the cable is positioned with the white tab facing up and that the cable is straight before push- ing in (closing) the clasp. See FIG. 28.

FIG. 28

12.Replace the bezel (31) onto the right meter cover half (18).

Ensure that all meter parts are positioned securely and in the correct location. Ensure that all cables are routed correctly throughout the meter and will not be pinched or kinked when the halves are reassembled See FIG. 29 and FIG. 30.

Ensure that the black antenna wire is not posi- tioned between the ribbon cables. Pull antenna away from the cable as shown. See FIG. 31.

FIG. 27

10.Disconnect the cables/wires (A, B, & C) that connect the bezel (31) to the circuit board (112). Discard the old bezel (31). See FIG. 27 and FIG. 28.

11.Reconnect the cables/wires (A, B, & C) from the new bezel (31) to the circuit board (112).