Programming the Meter
Programming the Meter
Graco recommends that meters be programmed prior to installation.
For ease of installation be sure to tag each meter with the corresponding PC meter number from the Matrix software. For example: Bay 1, 10W30. These tags are used for locating the corresponding meter in the assigned bay or location.
The electronic meter batteries need to be charged prior to use. See Instruction Manual 309502 for details.
Meter Programming
Prior to programming the electronic meters,
•Enter the transceiver and tank setup informa- tion into the Matrix PC software. If not done, the software will display an error when attempt- ing to set up meters.
•Navigate to the Meter Setup screen, input the meter parameters, then select PROGRAM for the meter being programmed.
1.Insert the battery. See Removing and Replacing the Battery on page 15.
2.When the battery is first inserted, the display shown in FIG. 2 appears.
3.To program a meter, simultaneously hold down both the left keypad button (A) and right keypad button (B) until both the ACTIVATE words on the display screen change to PROGRAM (appears on the left) and SELECT (appears on the right). Release buttons.
4.The screen indicates a Network and Transceiver ID. See FIG. 1.
PROGRAM MODE
2.02.003
NET WK ID A TRANS ID A
METER ID 500
PROGRAMSELECT 
FIG. 1
•If the ID information is correct, press the left (A) key- pad button labeled PROGRAM to complete the meter programming.
•If the ID information is incorrect, use the SELECT button and up/down arrow button to obtain the cor- rect ID settings. Then press the left (A) keypad but- ton labeled PROGRAM to complete the meter programming. See FIG. 2.
The meter must be at the ACTIVATE/ACTIVATE screen for it to be programmed. If you are in Work Order mode, put a test Work Order into the system so you can navigate to the ACTIVATE/ACTIVATE meter screen and
METER ID is the RF address assigned to the meter by the PC during programming.