5.The meter displays the appropriate programmed screen and a pop-up window displays on the PC indicating programming is complete. This process is repeated for each meter in the system.

The PC software allows a 5 minute period to pro- gram the meter.

If the electronic meter is unable to communicate with the PC during programming, the message NO SIGNAL appears at the top of the meter display.

6.Once the information is programmed into the elec- tronic meter, the meter can be connected to the dis- pensing hose in the corresponding bay. If the meter will not be immediately connected temporarily label it with the corresponding meter number and location (i.e. Meter 1, Bay 1, 10W30). The label assures the correct meter is installed in the correct location in the system. After the meter is installed in the correct location, the label can be removed. See Meter Installation on page 6.

If a programmed meter is moved or if the pro- grammed parameters need to be changed, the meter must be reprogrammed.

Programming the Meter

FIG. 2

If PC software revision is 2.01.29 or meter firmware revision is 2.00.053, meter will display 3 places to the right of the decimal rather than 2.

309497L

5

Page 5
Image 5
Graco 246008, 249881 instruction manual Programming the Meter