1.Relieve the Pressure.

WARNING

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8.

1.Remove the battery (11). See Parts Drawing for the 246008 and 249881 Electronic Meters on page 32.

2.Slide the rear boot (24) off the hose.

3.Remove the meter from the fluid hose.

4.Remove the impact guard (40) from the meter.

5.With a phillips screwdriver remove the four phillips screws (42) holding the bezel to the cover halves (18 & 19). See FIG. 32.

6.With a T-10 torx driver remove the remaining eleven screws (12) holding the cover halves together (18 & 19).

12

42 (both sides)

FIG. 32

7.Pull apart the two cover halves leaving all parts in the right cover half (18).

Service

All services to the meter should be done using the right cover half (18) of the meter. If parts should disen- gage as the covers are separated, reposition the parts back into the right cover half (18). See FIG. 33.

19

18

FIG. 33

8.Place the new right cover (18) along side of the meter.

9.Remove the old trigger components (13, 14, 22, 23, 36, & 37) and discard. See Parts Drawing for the 246008 and 249881 Electronic Meters on page 32.

10.Remove the RF Board (103) from the right meter housing (18) and disconnect the PSM switch (101) by pulling the cable from the RF Board (103). See FIG. 35.

11.Plug connector end of the new PSM switch (101) into the new RF Board (103) connector.

12.Transfer all remaining parts from the old meter cover half (18) to the new meter cover half (18). Discard the old meter cover halves (18) and (19).

13. The two ribs (E) of the new meter cover fit between the two bolts (F) of the meter housing. Be sure not to pinch or crimp the circular switch cable

(D) on the new cover half. See FIG. 34.

309497L

25

Page 25
Image 25
Graco 246008, 249881 instruction manual Relieve the Pressure