Miscellaneous Assemblies

Miscellaneous Mechanical Assemblies

Figure 54: PR70 Power Entry Bracket Assembly (LC0106)

Key:

Ref

P/N

Description

QTY

Ref

P/N

Description

QTY

1

119912

SCREW, PAN, M3X6, PHILLIPS, SS

3

11

84/0130-26/11

LABEL, PE

1

2

121018

ELBOW, SWVL, 3/8 X ¼ NPT, FXM, 90DE

1

12

LC0034

HARNESS, WIRE, REMOTE SIGNAL

1

3

120876

PWR SUPPLY, 24VDC, 40W, 100-240VAC IN

1

13

121178

VALVE, LOCKOUT, ¼ NPT

1

4

120882

FILTER, 1/4NPT

1

14

121179

QUIKCLAMP, ¼ NPT

2

5

120883

NUT, HEX, 7/8-14, MS

1

15

121180

MULTIPORT, [3] ¼ NPT

1

6

120910

PWR ENTRY, 120/240VAC, DUAL FUSE, EMI

1

16

94/0762/99

VALVE, RELIEF, ¼ NPT, M, 110PSI, SIL

1

7

120916

SCREW,FHSC, M3X0.5 X 10, SS

2

17

94/0430/99

PLUG, SKT HD, ¼ NPT, MS

2

8

120993

NUT, HEX, M5X0.8, WITH STAR WASHER

2

18

81/1054-4/11

FUSE 5X20MM, 4AMP, FAST, TYPE F, 250VAC

2

9

15K798

BRACKET, SWITCH, AIR

1

19

LC0031

CABLE ASSY, POWER IN

1

10

15K800

FITTING, BULKHEAD

1

 

 

 

 

To Replace the Fuses:

1.Remove the machine fuse holder from the PWR Entry module (6) by inserting a flat-head screwdriver between the holder and the back the PWR Entry module (The fuse holder is above where AC power is connected to the machine).

2.Replace the blown fuse(s) (18) into the fuse holder.

3.Re-install the holder into the PWR Entry Module.