Miscellaneous Machine Setups

Date and Time Settings (M4)

At the bottom right corner of the Run screen the date is shown in DD-MM-YY format and the time is shown in HH:MM, 24 hour format. The formats cannot be changed.

To set the current date:

From the Run screen, press , then press , and then press 3 times. The following screen will be displayed.

Figure 23: M4 Screen for Setting the Date and Time Key:

ACurrent Date (DD-MM-YY)

BCurrent Time (HH:MM, 24 Hour Format)

CCurrent Software Revision Dsp = Display Module FCM = Fluid Control Module

DDate Set ICON

ETime Set ICON.

IScreen Number (M4)

J & keys will navigate to adjacent screens.

1. Press . The M4 screen will appear as follows.

Figure 24: M4 Screen after Date Set Selection

3.Press and to enter the year.

4.Press to accept the change or to retain the previous setting.

5.Press and to enter the month.

6.Press to accept the change or to retain the previous setting.

7.Press and to enter the day.

8.Press to accept the change or to retain the previous setting.

9.Press twice to return to the Run screen.

To set the current time:

1. Press . The M4 screen will appear as follows.

Figure 25: M4 after Time Set Selection

2.Press and to enter the hour (0 - 23).

3.Press to accept the change or to retain the previous setting.

4.Press and to enter the minutes (0 - 59).

5.Press to accept the change or to retain the previous setting.

6.Press twice to return to the Run screen.

Tank Level Sensing and Velocity Change (“”) Options (C6)

If tank level sensors are installed into the system, an alarm is generated when a tank is almost empty. If the

feature is turned ON, a Tank A low (“”), a Tank B

low (“”), or a both tanks are low (“”) error will be generated if the condition exists.

The machine also measures the piston velocity and will generate an alarm if the piston velocity has changed significantly since the machine was last calibrated. A significant change is piston velocity, usually caused by a change in air pressure, can degrade shot size accuracy.

The user has the capability to turn the feature OFF

by selecting a level of 0%, or ON by selecting levels of 20%, 40% or 60%. For instance, if 40% is selected, and the piston velocity changes by + or – 40%, an error code will be generated after the corresponding shot to inform the operator of the situation. If the velocity

increases above the selected level, a error will be generated, and if the velocity decreases below the

selected level a error will be generated.

The feature is automatically disabled when the machine is in Operator mode, or when the machine is executing a purge shot.

From the Run screen, press , then press , then press 5 times. The following screen will be displayed.