Operation

Power Supply Operation

User Settings If you have a frequent or constant need for a specific voltage and current output, you (Save and can save these setpoints in the power supply’s memory as a user setting. Once a

Recall) setting is stored, it remains in the power supply’s memory after the unit is powered off.

Ten user setting memory locations are available, and each saves the following parameters:

Voltage setpoint

Current setpoint

Over-voltage protection setpoint (OVP)

Under-voltage protection setpoint and shutdown configuration (UVP)

Over-current protection setpoint and shutdown configuration (OCP)

Under-current protection setpoint and shutdown configuration (UCP)

Foldback protection mode and delay settings

AC Off auto recovery configuration (ACO)

OTP auto-recovery configuration

Aux line configuration

Voltage and current soft limits

Triggered setpoints and trigger source

Note All parameters are saved and used when the user setting is recalled. Therefore, you should set parameters that you do not care about to the factory defaults.

To store (save) settings:

*SAV <user-setting>

or the SCPI equivalent for multichannel addressed units

SYST<channel>:SAVE <user-setting>

where <user-setting> is an integer from 1 to 10.

Example:

*SAV 1 will save all the present settings to user setting location 1.

To recall settings:

*RCL <user-setting>

To save default settings:

*SDS <user-setting>