Features and Specifications
Specifications
Table 1.2 Specifications for XFR 1200 W with
Models |
|
|
|
|
|
Program Resolution |
|
|
|
|
|
Voltage | 1.16mV | 1.8mV | 3.08mV | 5.4mV | 6.2mV |
Current | 19.6mA | 14mA | 8.4mA | 5.4mA | 4.2mA |
Program Accuracy1 |
|
|
|
|
|
Voltage | 10mV | 50mV | 75mV | 75mV | 75mV |
| ±0.12% | ±0.12% | ±0.12% | ±0.3% | ±0.3% |
Current | 500mA | 460mA | 250mA | 200mA | 150mA |
| ±0.1% | ±0.1% | ±0.1% | ±0.1% | ±0.15% |
|
|
|
|
|
|
Readback Resolution |
|
|
|
|
|
Voltage | 1.16mV | 1.8mV | 3.08mV | 5.4mV | 6.2mV |
Current | 19.6mA | 14mA | 8.4mA | 5.4mA | 4.2mA |
|
|
|
|
|
|
Readback Accuracy1 |
|
|
|
|
|
Voltage | 30mV | 60mV | 75mV | 75mV | 75mV |
| ±0.12% | ±0.12% | ±0.12% | ±0.3% | ±0.3% |
Current | 500mA | 460mA | 250mA | 200mA | 150mA |
| ±0.1% | ±0.1% | ±0.1% | ±0.1% | ±0.15% |
Models |
|
|
|
|
|
Program Resolution |
|
|
|
|
|
Voltage | 9.2mV | 15.4mV | 23.1mV | 46.2mV | 92.4mV |
Current | 2.8mA | 1.68mA | 1.12mA | 0.56mA | 0.28mA |
Program Accuracy1 |
|
|
|
|
|
Voltage | 150mV | 150mV | 225mV | 225mV | 250mV |
| ±0.25% | ±0.35% | ±0.35% | ±0.35% | ±0.35% |
Current | 120mA | 80mA | 80mA | 80mA | 50mA |
| ±0.1% | ±0.1% | ±0.1% | ±0.1% | ±0.1% |
Readback Resolution |
|
|
|
|
|
Voltage | 9.2mV | 15.4mV | 23.1mV | 46.2mV | 92.4mV |
Current | 2.8mA | 1.68mA | 1.12mA | 0.56mA | 0.28mA |
Readback Accuracy1 |
|
|
|
|
|
Voltage | 150mV | 150mV | 225mV | 225mV | 250mV |
| ±0.25% | ±0.35% | ±0.35% | ±0.35% | ±0.35% |
Current | 120mA | 80mA | 80mA | 80mA | 50mA |
| ±0.1% | ±0.1% | ±0.1% | ±0.1% | ±0.1% |
1.Apply accuracy specifications according to the following voltage program accuracy example: Set a model XFR
The expected result will be within the range of 10 volts ± 75mV ± 0.12% of the set voltage of 10 volts.
20 | Operating Manual for Multichannel Functionality |