Features and Specifications

Specifications

Table 1.2 Specifications for XFR 1200 W with GPIB-M or CANbus

Models

7.5-140

12-100

20-60

35-35

40-30

Program Resolution

 

 

 

 

 

Voltage

1.16mV

1.8mV

3.08mV

5.4mV

6.2mV

Current

19.6mA

14mA

8.4mA

5.4mA

4.2mA

Program Accuracy1

 

 

 

 

 

Voltage

10mV

50mV

75mV

75mV

75mV

 

±0.12%

±0.12%

±0.12%

±0.3%

±0.3%

Current

500mA

460mA

250mA

200mA

150mA

 

±0.1%

±0.1%

±0.1%

±0.1%

±0.15%

 

 

 

 

 

 

Readback Resolution

 

 

 

 

 

Voltage

1.16mV

1.8mV

3.08mV

5.4mV

6.2mV

Current

19.6mA

14mA

8.4mA

5.4mA

4.2mA

 

 

 

 

 

 

Readback Accuracy1

 

 

 

 

 

Voltage

30mV

60mV

75mV

75mV

75mV

 

±0.12%

±0.12%

±0.12%

±0.3%

±0.3%

Current

500mA

460mA

250mA

200mA

150mA

 

±0.1%

±0.1%

±0.1%

±0.1%

±0.15%

Models

60-20

100-12

150-8

300-4

600-2

Program Resolution

 

 

 

 

 

Voltage

9.2mV

15.4mV

23.1mV

46.2mV

92.4mV

Current

2.8mA

1.68mA

1.12mA

0.56mA

0.28mA

Program Accuracy1

 

 

 

 

 

Voltage

150mV

150mV

225mV

225mV

250mV

 

±0.25%

±0.35%

±0.35%

±0.35%

±0.35%

Current

120mA

80mA

80mA

80mA

50mA

 

±0.1%

±0.1%

±0.1%

±0.1%

±0.1%

Readback Resolution

 

 

 

 

 

Voltage

9.2mV

15.4mV

23.1mV

46.2mV

92.4mV

Current

2.8mA

1.68mA

1.12mA

0.56mA

0.28mA

Readback Accuracy1

 

 

 

 

 

Voltage

150mV

150mV

225mV

225mV

250mV

 

±0.25%

±0.35%

±0.35%

±0.35%

±0.35%

Current

120mA

80mA

80mA

80mA

50mA

 

±0.1%

±0.1%

±0.1%

±0.1%

±0.1%

1.Apply accuracy specifications according to the following voltage program accuracy example: Set a model XFR 20-60 power supply to 10 volts.

The expected result will be within the range of 10 volts ± 75mV ± 0.12% of the set voltage of 10 volts.

20

Operating Manual for Multichannel Functionality (GPIB-M)

Page 22
Image 22
Xantrex Technology GPIB-M-XFR3, GPIB-M-XHR manual Models 140 12-100 20-60 35-35 40-30, Models 60-20 100-12 150-8 300-4 600-2