Features and Specifications

Specifications

Table 1.3 Specifications for XFR 2800 W with GPIB-M or CANbus

Models

7.5-300

12-220

20-130

33-85

40-70

Program Resolution

 

 

 

 

 

Voltage

1.16mV

1.8mV

3.08mV

5.1mV

6.2mV

Current

42.0mA

30.8mA

18.2mA

13.0mA

9.8mA

Program Accuracy1

 

 

 

 

 

Voltage

10mV

50mV

75mV

75mV

75mV

 

±0.12%

±0.12%

±0.12%

±0.3%

±0.3%

Current

900mA

750mA

500mA

425mA

350mA

 

±0.1%

±0.1%

±0.1%

±0.1%

±0.15%

 

 

 

 

 

 

Readback Resolution

 

 

 

 

 

Voltage

1.16mV

1.8mV

3.08mV

5.1mV

6.2mV

Current

42.0mA

30.8mA

18.2mA

13.0mA

9.8mA

 

 

 

 

 

 

Readback Accuracy

 

 

 

 

 

Voltage

30mV

60mV

75mV

75mV

75mV

 

±0.12%

±0.12%

±0.12%

±0.3%

±0.3%

Current

900mA

750mA

500mA

425mA

350mA

 

±0.1%

±0.1%

±0.1%

±0.1%

±0.1%

Models

60-46

100-28

150-18

300-9

600-4

Program Resolution

 

 

 

 

 

Voltage

9.2mV

15.4mV

23.1mV

46.2mV

92.4mV

Current

6.44mA

3.92mA

2.52mA

1.26mA

0.56mA

Program Accuracy1

 

 

 

 

 

Voltage

150mV

150mV

225mV

225mV

250mV

 

±0.25%

±0.35%

±0.35%

±0.35%

±0.35%

Current

250mA

140mA

120mA

80mA

80mA

 

±0.1%

±0.1%

±0.1%

±0.1%

±0.1%

Readback Resolution

 

 

 

 

 

Voltage

9.2mV

15.4mV

23.1mV

46.2mV

92.4mV

Current

6.44mA

3.92mA

2.52mA

1.26mA

0.56mA

Readback Accuracy1

 

 

 

 

 

Voltage

150mV

150mV

225mV

225mV

250mV

 

±0.25%

±0.35%

±0.35%

±0.35%

±0.35%

Current

250mA

140mA

120mA

80mA

80mA

 

±0.1%

±0.15%

±0.1%

±0.1%

±0.1%

1.Apply accuracy specifications according to the following voltage program accuracy example: Set a model XFR 20-130 power supply to 10 volts.

The expected result will be within the range of 10 volts ± 75mV ± 0.12% of the set voltage of 10 volts

Release 2.1

21

Page 23
Image 23
Xantrex Technology GPIB-M-HPD, GPIB-M-XHR Models 300 12-220 20-130 33-85 40-70, Models 60-46 100-28 150-18 300-9 600-4