Release 2.1

115

Expressions

Table B.15Expressions

Expression

Details

 

 

aux_line_mnemonic

Define the output of the auxiliary line.The possible values are NONE, ON, OFF, OVOLtage,

 

UVOLtage, OCURrent, UCURrent, ACOFf, OTEMperature, SPRotection, UNRegulated, FOLD, CC,

 

CV, CP.

 

 

channel

The address for a multichannel slave. An integer value in the range 2 to 50.

 

 

codeword

A string representing any 4-digit positive integer.

 

 

current

A numeric value as defined by SCPI. May also be MAXimum or MINimum. May include

 

current-related suffix units such as “mA”, “uA”, “A” etc. Range may be 0 to 103% of model’s rated

 

current.

 

 

delay

A length of time in the range 0 to 60 seconds. May include time-related suffix units such as “S”,

 

“MIN”, “mS”, “uS” etc. By default, the value is in seconds.

 

 

ESE-word

Range 0–255. An 8-bit status mask for the Standard Event Status Register that determines which

 

bits are OR’d to form the ESB bit in the Status Byte Register.

 

 

GPIB_address

The address for a GPIB controlled unit. An integer value in the range 1 to 30.

 

 

on-off-state

A Boolean indicator of a state. Possible values are ON, OFF, 0 (off), or 1 (on).

 

 

OVP_level

A numeric value as defined by SCPI. May also be MAXimum or MINimum. May include

 

voltage-related suffix units such as “mV”, “uV”, “V”, etc. Range is 0 to 103% of model’s rated voltage.

 

 

setting_location

A numeric indication of an internal set of setting registers. An integer value in the range 1 to 10.

 

 

sequence_count

Number of times a sequence is to be repeated. Range is 1 to 9999.

 

 

sequence_number

The name of an auto sequence program. Range is 1 to 10. The suffix is part of the SEQUENCE

 

command name and is not a parameter.

 

 

status-enable

A 16-bit status mask for any condition register that determines which bits are to be used for

 

synthesizing the summary bit of that register.

 

 

step_number

The step number of an auto sequence program. Possibly considered a SCPI suffix. Range is 1 to

 

99.

 

 

step_time

The duration of an auto sequence step in the format hh:mm:ss.s.

 

May include time-related suffix units such as “S”, “MIN”, “mS”, “uS”, etc. By default, the value is in

 

seconds.

 

 

voltage

A numeric value as defined by SCPI. May also be MAXimum or MINimum. May include

 

voltage-related suffix units such as “mV”, “uV”, “V”, etc. Range is 0 to 103% of model’s rated voltage.

 

 

SCPI Command Reference

Expressions

Page 117
Image 117
Xantrex Technology GPIB-M-XPD, GPIB-M-XHR, GPIB-M-XT, GPIB-M-XFR3, GPIB-M-HPD manual Expressions, Expression Details