Operating Manual for Multichannel Functionality (GPIB-M)

Table B.3Commands for Output Control

Function

SCPI Command

Description

Query

 

 

 

 

Set (Immediate) Current

[[:]SOURce][<channel>]:CURRent[:LEVel][:IMMediate][:A

Change current setpoint

Yes

Setpoint

MPLitude] {<current>MAXimumMINimum}

 

 

Set Triggered Current

[[:]SOURce][<channel>]:CURRent[:LEVel]:TRIGgered[:AMP

Change triggered current setpoint

Yes

Setpoint

Litude] {<current>MAXimumMINimumDEFault}

 

 

 

 

 

 

Set (Immediate) Voltage

[[:]SOURce][<channel>]:VOLTage[:LEVel][:IMMediate][:A

Change voltage setpoint

Yes

Setpoint

MPLitude] {<voltage>MAXimumMINimum}

 

 

 

 

 

 

Set Triggered Voltage

[[:]SOURce][<channel>]:VOLTage[:LEVel]:TRIGgered[:AMP

Change triggered votlage setpoint

Yes

Setpoint

Litude] {<voltage>MAXimumMINimumDEFault}

 

 

 

 

 

 

Set Voltage Slew Rate

[[:]SOURce][<channel>]:VOLTage:SLEW:STEP{<slewrate-vo

Sets the voltage slew rate voltage change

Yes

Voltage

ltage>MAXimumMINimumDEFault}

for the programmed time interval

 

Set Voltage Slew Rate

[[:]SOURce][<channel>]:VOLTage:SLEW:INTerval{<slewrat

Sets the voltage slew rate time interval for

Yes

Interval

e-interval>MAXimumMINimumDEFault}

the programmed voltage change

 

Set Over Current

[[:]SOURce][<channel>]:CURRent:PROTection[:OVER][:LEV

Set the over current protection level

Yes

Protection Level

el] {<current>MAXimumMINimum}

 

 

 

 

 

 

Set Over Current

[[:]SOURce][<channel>]:CURRent:PROTection[:OVER]:STAT

Select over current protection to

Yes

Protection

e <on-off-state>

shutdown(ON) or set alarm (OFF)

 

Shutdown State

 

 

 

Query Over Current

[[:]SOURce][<channel>]:CURRent:PROTection[:OVER]:TRIP

Query if over current protection mechanism

N/A

Protection Tripped

ped?

has tripped

 

 

 

 

 

Set Under Current

[[:]SOURce][<channel>]:CURRent:PROTection:UNDer[:LEVe

Set under current protection level

Yes

Protection Level

l] {<current>MAXimumMINimum}

 

 

 

 

 

 

Set Under Current

[[:]SOURce][<channel>]:CURRent:PROTection:UNDer:STATe

Select under current protection to shutdown

Yes

Protection

<on-off-state>

(ON) or set alarm (OFF)

 

Shutdown State

 

 

 

Query Under Current

[[:]SOURce][<channel>]:CURRent:PROTection:UNDer:TRIPp

Query if under current protection

N/A

Protection Tripped

ed?

mechanism has tripped

 

 

 

 

 

Set Over Voltage

[[:]SOURce][<channel>]:VOLTage:PROTection[:OVER][:LEV

Set the over voltage protection level

Yes

Protection Level

el] {<voltage>MAXimumMINimum}

 

 

 

 

 

 

Query Over Voltage

[SOURce][<channel>]:VOLTage:PROTection[:OVER]:TRIPped

Query if over voltage protection mechanism

N/A

Protection Tripped

?

has tripped

 

Set Under Voltage

[[:]SOURce][<channel>]:VOLTage:PROTection:UNDer[:LEVe

Set under voltage protection level

N/A

Protection Level

l] {<voltage>MAXimumMINimum}

 

 

 

 

 

 

Set Under Voltage

[[:]SOURce][<channel>]:VOLTage:PROTection:UNDer:STATe

Select under voltage protection to shutdown

Yes

Protection

<on-off-state>

(ON) or set alarm (OFF)

 

Shutdown State

 

 

 

Query Under Voltage

[[:]SOURce][<channel>]:VOLTage:PROTection:UNDer:TRIPp

Query if under voltage protection

N/A

Protection Tripped

ed?

mechanism has tripped

 

Set High Current Limit

[[:]SOURce][<channel>]:CURRent:LIMit:HIGH

Set upper limit of current setpoint range (soft

Yes

 

{<current>MAXimumMINimum}

limits)

 

 

 

 

 

Set Low Current Limit

[[:]SOURce][<channel>]:CURRent:LIMit:LOW

Set lower limit of current setpoint range (soft

Yes

 

{<current>MAXimumMINimum}

limits)

 

 

 

 

 

SCPI Command Reference

SCPI Command Summary

Page 108
Image 108
Xantrex Technology GPIB-M-XHR, GPIB-M-XT, GPIB-M-XPD, GPIB-M-XFR3, GPIB-M-HPD manual Table B.3Commands for Output Control