Features and Specifications

Specifications

Table 1.4 Specifications for XHR 1000 W with GPIB-M or CANbus

Models

7.5-130

20-50

33-33

40-25

60-18

Program Resolution

 

 

 

 

 

Voltage

1.16mV

1.8mV

3.08mV

6.2mV

9.2mV

Current

42.0mA

30.8mA

18.2mA

9.8mA

6.44mA

Program Accuracy1

 

 

 

 

 

Voltage

10mV

50mV

75mV

75mV

150mV

 

±0.12%

±0.12%

±0.12%

±0.3%

±0.25%

Current

900mA

750mA

500mA

350mA

250mA

 

±0.1%

±0.1%

±0.1%

±0.1%

±0.1%

 

 

 

 

 

 

Readback Resolution

 

 

 

 

 

Voltage

1.16mV

1.8mV

3.08mV

6.2mV

9.2mV

Current

42.0mA

30.8mA

18.2mA

9.8mA

6.44mA

 

 

 

 

 

 

Readback Accuracy1

 

 

 

 

 

Voltage

30mV

60mV

75mV

75mV

150mV

 

±0.12%

±0.12%

±0.12%

±0.3%

±0.25%

Current

900mA

750mA

500mA

350mA

250mA

 

±0.1%

±0.1%

±0.1%

±0.1%

±0.1%

Models

100-10

150-7

300-3.5

600-1.7

Program Resolution

 

 

 

 

Voltage

15.4mV

23.1mV

46.2mV

92.4mV

Current

3.92mA

2.52mA

1.26mA

0.56mA

Program Accuracy1

 

 

 

 

Voltage

150mV

225mV

225mV

250mV

 

±0.35%

±0.35%

±0.35%

±0.35%

Current

140mA

120mA

80mA

80mA

 

±0.15%

±0.1%

±0.1%

±0.1%

Readback Resolution

 

 

 

 

Voltage

15.4mV

23.1mV

46.2mV

92.4mV

Current

3.92mA

2.52mA

1.26mA

0.56mA

Readback Accuracy1

 

 

 

 

Voltage

150mV

225mV

225mV

250mV

 

±0.35%

±0.35%

±0.35%

±0.35%

Current

140mA

120mA

80mA

80mA

 

±0.15%

±0.1%

±0.1%

±0.1%

1.Apply accuracy specifications according to the following voltage program accuracy example: Set a model XHR 20-50 power supply to 10 volts.

The expected result will be within the range of 10 volts ± 50mV ± 0.12% of the set voltage of 10 volts.

22

Operating Manual for Multichannel Functionality (GPIB-M)

Page 24
Image 24
Xantrex Technology GPIB-M-XHR, GPIB-M-XFR manual Models 130 20-50 33-33 40-25 60-18, Models 100-10 150-7 300-3.5 600-1.7