Features and Specifications
Specifications
Table 1.4 Specifications for XHR 1000 W with
Models |
|
|
|
|
|
Program Resolution |
|
|
|
|
|
Voltage | 1.16mV | 1.8mV | 3.08mV | 6.2mV | 9.2mV |
Current | 42.0mA | 30.8mA | 18.2mA | 9.8mA | 6.44mA |
Program Accuracy1 |
|
|
|
|
|
Voltage | 10mV | 50mV | 75mV | 75mV | 150mV |
| ±0.12% | ±0.12% | ±0.12% | ±0.3% | ±0.25% |
Current | 900mA | 750mA | 500mA | 350mA | 250mA |
| ±0.1% | ±0.1% | ±0.1% | ±0.1% | ±0.1% |
|
|
|
|
|
|
Readback Resolution |
|
|
|
|
|
Voltage | 1.16mV | 1.8mV | 3.08mV | 6.2mV | 9.2mV |
Current | 42.0mA | 30.8mA | 18.2mA | 9.8mA | 6.44mA |
|
|
|
|
|
|
Readback Accuracy1 |
|
|
|
|
|
Voltage | 30mV | 60mV | 75mV | 75mV | 150mV |
| ±0.12% | ±0.12% | ±0.12% | ±0.3% | ±0.25% |
Current | 900mA | 750mA | 500mA | 350mA | 250mA |
| ±0.1% | ±0.1% | ±0.1% | ±0.1% | ±0.1% |
Models |
|
|
|
|
Program Resolution |
|
|
|
|
Voltage | 15.4mV | 23.1mV | 46.2mV | 92.4mV |
Current | 3.92mA | 2.52mA | 1.26mA | 0.56mA |
Program Accuracy1 |
|
|
|
|
Voltage | 150mV | 225mV | 225mV | 250mV |
| ±0.35% | ±0.35% | ±0.35% | ±0.35% |
Current | 140mA | 120mA | 80mA | 80mA |
| ±0.15% | ±0.1% | ±0.1% | ±0.1% |
Readback Resolution |
|
|
|
|
Voltage | 15.4mV | 23.1mV | 46.2mV | 92.4mV |
Current | 3.92mA | 2.52mA | 1.26mA | 0.56mA |
Readback Accuracy1 |
|
|
|
|
Voltage | 150mV | 225mV | 225mV | 250mV |
| ±0.35% | ±0.35% | ±0.35% | ±0.35% |
Current | 140mA | 120mA | 80mA | 80mA |
| ±0.15% | ±0.1% | ±0.1% | ±0.1% |
1.Apply accuracy specifications according to the following voltage program accuracy example: Set a model XHR
The expected result will be within the range of 10 volts ± 50mV ± 0.12% of the set voltage of 10 volts.
22 | Operating Manual for Multichannel Functionality |