Xantrex Technology GPIB-M-XFR, GPIB-M-XHR, GPIB-M-XT, GPIB-M-XPD Models 18-30 33-16 60-9 120-4.5

Models: GPIB-M-XT GPIB-M-XFR GPIB-M-XFR3 GPIB-M-XHR GPIB-M-XPD GPIB-M-HPD

1 134
Download 134 pages 21.51 Kb
Page 25
Image 25

Features and Specifications

Specifications

Table 1.5 Specifications for XPD 500 W with GPIB-M or CANbus

Models

7.5-67

18-30

33-16

60-9

120-4.5

Program Resolution

 

 

 

 

 

Voltage

1.2mV

4.6mV

5.1mV

9.3mV

18.6mV

Current

5.2mA

3.6mA

2.9mA

1.3mA

0.7mA

Program Accuracy1

10mV

75mV

75mV

150mV

180mV

Voltage

 

±0.12%

±0.12%

±0.12%

±0.3%

±0.25%

Current

250mA

140mA

115mA

80mA

80mA

 

±0.1%

±0.1%

±0.15%

±0.15%

±0.1%

 

 

 

 

 

 

Readback Resolution

 

 

 

 

 

Voltage

1.2mV

4.6mV

5.1mV

9.3mV

18.6mV

Current

5.2mA

3.6mA

2.4mA

1.3mA

0.7mA

 

 

 

 

 

 

Readback Accuracy1

 

 

 

 

 

Voltage

30mV

75mV

75mV

150mV

180mV

 

±0.12%

±0.12%

±0.2%

±0.3%

±0.25%

Current

250mA

140mA

115mA

80mA

80mA

 

±0.1%

±0.1%

±0.15%

±0.15%

±0.1%

1.Apply accuracy specifications according to the following voltage program accuracy example: Set a model XPD 18-30 power supply to 10 volts.

The expected result will be within the range of 10 volts ± 75mV ± 0.12% of the set voltage of 10 volts.

Table 1.6 Specifications for XT 60 W with GPIB-M or CANbus

Models

7-6

15-4

20-3

30-2

60-1

120-0.5

250-0.25

Program Resolution

 

 

 

 

 

 

 

Voltage

1.1mV

2.4mV

3.1mV

4.7mV

9.3mV

17mV

17mV

Current

1.0mA

0.6mA

0.5mA

0.3mA

0.2mA

0.1mA

0.1mA

 

 

 

 

 

 

 

 

Program Accuracy1

 

 

 

 

 

 

 

Voltage

10mV

20mV

20mV

30mV

200mV

400mV

400mV

 

±0.1%

±0.1%

±0.15%

±0.15%

±0.15%

±0.15%

±0.15%

Current

110mA

70mA

50mA

40mA

26mA

13mA

13mA

 

±0.15%

±0.15%

±0.15%

±0.15%

±0.2%

±0.2%

±0.2%

Readback Resolution

 

 

 

 

 

 

 

Voltage

1.1mV

2.4mV

3.1mV

4.7mV

9.3mV

17mV

17mV

Current

1.0mA

0.6mA

0.5mA

0.3mA

0.2mA

0.1mA

0.1mA

Readback Accuracy1

 

 

 

 

 

 

 

Voltage

10mV

10mV

10mV

15mV

35mV

70mV

70mV

 

±0.15%

±0.1%

±0.1%

±0.1%

±0.15%

±0.15%

±0.15%

Current

110mA

70mA

50mA

40mA

26mA

13mA

13mA

 

±0.15%

±0.15%

±0.15%

±0.15%

±0.2%

±0.2%

±0.2%

1.Apply accuracy specifications according to the following voltage program accuracy example: Set a model XT 15-4 power supply to 10 volts.

The expected result will be within the range of 10 volts ± 20mV ± 0.1% of the set voltage of 10 volts.

Release 2.1

23

Page 25
Image 25
Xantrex Technology GPIB-M-XFR, GPIB-M-XHR Models 18-30 33-16 60-9 120-4.5, Models 15-4 20-3 30-2 60-1 120-0.5 250-0.25