Master | The Master Summary Status message indicates that the power supply has at least one |
Summary | reason for requesting service. Although the MSS message is sent in bit position 5 of |
Status (MSS) | the response to *STB?, it is not sent in response to a serial poll and not considered |
| part of the Status Byte. |
| MSS is TRUE if: |
| • Status Byte bit 0 AND Service Request Enable Register bit 0, or |
| • Status Byte bit 1 AND Service Request Enable Register bit 1, or |
| • Status Byte bit 2 AND Service Request Enable Register bit 2, or |
| • Status Byte bit 3 AND Service Request Enable Register bit 3, or |
| • Status Byte bit 4 AND Service Request Enable Register bit 4, or |
| • Status Byte bit 5 AND Service Request Enable Register bit 5, or |
| • Status Byte bit 7 AND Service Request Enable Register bit 7. |
Request | RQS is TRUE if the Service Request Enable Register has a bit set and there is a |
Service | corresponding bit within the Status Byte. |
(RQS) | The SRQ line of the GPIB will be set. The SRQ annuciator will be lit. |