112
Operating Manual for Multichannel Functionality
Query the Standard Event | [:]STATus[<channel>]:STANdard[:EVENt]? | See Table 4.10, on page 78. | N/A |
register (ESR?) |
|
|
|
Enable the Standard | [:]STATus[<channel>]:STANdard:ENABle | See Table 4.10, on page 78. | Yes |
Event register |
|
|
|
(*ESE,*ESE?) |
|
|
|
|
|
|
|
Query the Status Byte | [:]STATus[<channel>]:SBYTe[:EVENt]? | See Table 4.11, on page 79. | N/A |
(*STB) |
|
|
|
Service Request Enable | [:]STATus[<channel>]:SREQuest:ENABle | Set the bits in the Service Request Enable | Yes |
(*SRE,*SRE?) |
| Register. |
|
|
|
|
|
Table B.11Protection Commands
Function | SCPI Command | Description | Query |
Set Over Temperature | [:]SENSe[<channel>]:TEMPerature:PROTection:LATCh | Select if output is latched off or auto | Yes |
Response | recovers in the case of an over temperature |
| |
|
| condition |
|
Query Over Temperature | [:]SENSe[<channel>]:TEMPerature:PROTection:TRIPped? | Query temperature protection tripped | N/A |
Protection Tripped |
|
|
|
Set AC Fail Response | [:]SENSe[<channel>]:VOLTage:AC:PROTection:LATCh | Select if output is latched off or auto | Yes |
| recovers in the case of an AC Fail |
| |
|
|
|
|
Query AC Fail Protection | [:]SENSe[<channel>]:VOLTage:AC:PROTection:TRIPped? | Query AC protection circuit tripped | N/A |
Tripped |
|
|
|
Table B.12User Lines
Function | SCPI Command | Description | Query |
Select polarity of Auxiliary | [:]OUTPut[<channel>]:AUXiliary<AB>:POLarity | Configure the polarity of the auxiliary line | Yes |
Lines | {HIGHLOW} |
|
|
Select Source of Auxiliary | [:]OUTPut[<channel>]:AUXiliary<AB>:SOURce | Configure the auxiliary line | Yes |
Line State | <aux_line_mnemonic> |
|
|
|
|
|
|
Query state of Auxiliary | [:]OUTPut[<channel>]:AUXiliary<AB>:STATe? | Query the state of the auxiliary line | N/A |
Line |
|
|
|
Table B.13Output State
Function | SCPI Command | Description | Query |
|
|
|
|
Set Output State | [:]OUTPut[<channel>][:STATe] | Enable/disable the power supply output. | Yes |
|
|
|
|
Set Output State at | [:]OUTPut[<channel>]:PON:STATe | Selects the state of the output at | Yes |
|
|
| |
[:]OUTPut[<channel>]:PON:RECall | Configure the supply to recall last setting, | Yes | |
| {PRESetUSER<setting_location>SEQ<sequence_number>} | one of the user settings, factory preset |
|
|
| values or to enable an auto sequence. |
|
SCPI Command Reference
SCPI Command Summary