112

Operating Manual for Multichannel Functionality (GPIB-M)

Query the Standard Event

[:]STATus[<channel>]:STANdard[:EVENt]?

See Table 4.10, on page 78.

N/A

register (ESR?)

 

 

 

Enable the Standard

[:]STATus[<channel>]:STANdard:ENABle

See Table 4.10, on page 78.

Yes

Event register

 

 

 

(*ESE,*ESE?)

 

 

 

 

 

 

 

Query the Status Byte

[:]STATus[<channel>]:SBYTe[:EVENt]?

See Table 4.11, on page 79.

N/A

(*STB)

 

 

 

Service Request Enable

[:]STATus[<channel>]:SREQuest:ENABle <status-enable>

Set the bits in the Service Request Enable

Yes

(*SRE,*SRE?)

 

Register.

 

 

 

 

 

Table B.11Protection Commands

Function

SCPI Command

Description

Query

Set Over Temperature

[:]SENSe[<channel>]:TEMPerature:PROTection:LATCh

Select if output is latched off or auto

Yes

Response

<on-off-state>

recovers in the case of an over temperature

 

 

 

condition

 

Query Over Temperature

[:]SENSe[<channel>]:TEMPerature:PROTection:TRIPped?

Query temperature protection tripped

N/A

Protection Tripped

 

 

 

Set AC Fail Response

[:]SENSe[<channel>]:VOLTage:AC:PROTection:LATCh

Select if output is latched off or auto

Yes

 

<on-off-state>

recovers in the case of an AC Fail

 

 

 

 

 

Query AC Fail Protection

[:]SENSe[<channel>]:VOLTage:AC:PROTection:TRIPped?

Query AC protection circuit tripped

N/A

Tripped

 

 

 

Table B.12User Lines

Function

SCPI Command

Description

Query

Select polarity of Auxiliary

[:]OUTPut[<channel>]:AUXiliary<AB>:POLarity

Configure the polarity of the auxiliary line

Yes

Lines

{HIGHLOW}

 

 

Select Source of Auxiliary

[:]OUTPut[<channel>]:AUXiliary<AB>:SOURce

Configure the auxiliary line

Yes

Line State

<aux_line_mnemonic>

 

 

 

 

 

 

Query state of Auxiliary

[:]OUTPut[<channel>]:AUXiliary<AB>:STATe?

Query the state of the auxiliary line

N/A

Line

 

 

 

Table B.13Output State

Function

SCPI Command

Description

Query

 

 

 

 

Set Output State

[:]OUTPut[<channel>][:STATe] <on-off-state>

Enable/disable the power supply output.

Yes

 

 

 

 

Set Output State at

[:]OUTPut[<channel>]:PON:STATe <on-off-state>

Selects the state of the output at power-on

Yes

Power-On

 

 

 

Power-On Configuration

[:]OUTPut[<channel>]:PON:RECall

Configure the supply to recall last setting,

Yes

 

{PRESetUSER<setting_location>SEQ<sequence_number>}

one of the user settings, factory preset

 

 

 

values or to enable an auto sequence.

 

SCPI Command Reference

SCPI Command Summary

Page 114
Image 114