Xantrex Technology GPIB-M-XPD, GPIB-M-XHR, GPIB-M-XT, GPIB-M-XFR3, GPIB-M-HPD Protection SHUTdown

Models: GPIB-M-XT GPIB-M-XFR GPIB-M-XFR3 GPIB-M-XHR GPIB-M-XPD GPIB-M-HPD

1 134
Download 134 pages 21.51 Kb
Page 75
Image 75

Status Registers

Overview

SHUTdown The Shutdown sub-register indicates the cause of the power supply shutdown. More Sub-Registerthan one bit may be active, and multiple actions will be required to enable the output.

The protection shutdown sub-register indicates which protection mechanisms have caused the power supply to shutdown.

Table 4.3 SHUTdown Sub-Register

 

Bit

Bit Weight

Bit Name

Description

 

 

0

1

PROTectio

The power supply is shut down by a power

 

 

 

 

n Summary

supply protection mechanism.

 

 

1

2

INTerlock

The power supply is shut down by INTerlock

 

 

 

 

 

signal.

 

 

 

 

 

 

 

 

 

2

4

COMMand

The power supply is shut down by a command.

 

Protection

 

 

 

 

 

 

 

 

 

 

 

 

SHUTdown

Table 4.4 Protection SHUTdown Sub-Register

 

Sub-Register

 

 

Bit

Bit Weight

Bit Name

 

Description

 

 

 

 

 

 

 

 

0

1

Over VOLTage

Over voltage protection has tripped

 

 

 

 

 

 

 

 

1

2

Under VOLTage

Under voltage protection has tripped

 

 

 

 

 

 

 

 

2

4

Over CURrent

Over current protection has tripped

 

 

 

 

 

 

 

 

3

8

Under CURrent

Under current protection has tripped

 

 

 

 

 

 

 

 

 

4

16

Reserved

 

 

 

 

 

 

 

 

 

 

 

5

32

Reserved

 

 

 

 

 

 

 

 

 

 

 

6

64

AC Fail

 

AC Fail protection has tripped

 

 

 

 

 

 

 

 

7

128

Over Temperature

Over temperature protection has tripped

 

 

 

 

 

 

 

 

 

8

256

SENSe

 

Sense protection has tripped

 

 

 

 

 

 

 

 

 

9

512

FOLDback

 

Foldback protection has tripped

 

 

 

 

 

 

 

 

 

10

1024

Output Fail

 

The power supply is shutdown by a

 

 

 

 

 

 

hardware circuit that monitors the output

 

and compares it to the setpoint. Shutdown could indicate a bridge failure. A temporary condition may be caused by transients.

Remote This identifies which remote interface is controlling the unit. Only one bit is active CONtrol at a time with the exception of analog control, where voltage or current alone, or both

Sub-Registermay be under remote control. Current share mode is considered to be under local control, even though the user cannot adjust the voltage setting from the front panel.

Release 2.1

73

Page 75
Image 75
Xantrex Technology GPIB-M-XPD, GPIB-M-XHR, GPIB-M-XFR Protection SHUTdown, Sub-Register Bit Bit Weight Bit Name Description