Technical Data

Technical Data

Category

Data

 

 

Metering Pump Effective Area

80 – 960 mm2 (0.124 – 1.49 in2) per side

 

 

Small Air Cylinder Effective Area

4560 mm2 (7.07 in2)

 

 

Large Air Cylinder Effective Area

10260 mm2 (15.9 in2)

 

 

Maximum Stroke Length

38.1 mm (1.50 in)

 

 

Minimum Stroke Length

5.8 mm (0.23 in)

 

 

Volume per Cycle

2 – 70 cc (0.12 – 4.3 in3)

 

 

Pump Cycles per 1L (0.26 gal)

500 – 14.3

 

 

Ratios (fixed)

1:1 to 12:1 (depending upon cylinders selected)

 

 

Maximum Fluid Working Pressure

3000 psi (20.7 MPa, 207 bar)

 

 

Maximum Air Input Pressure

100 psi (0.7 MPa, 7 bar)

 

 

Maximum Cycle Rate

30 cpm

 

 

Maximum Operating Temperature

70 C (160 F), nylon pistons 50 C (120 F) UHMWPE pistons or PE Tanks

 

 

Air Inlet Size

¼ NPT (f)

 

 

Pump Fluid Outlet Size

-03, -04, -06, -08 or –12 JIC fittings for 3/16 in (4.8 mm), ¼ in (6.4 mm), 3/8 in

 

(9.5 mm), ½ in (12.7 mm), ¾ in (19.1 mm) hoses

 

 

Wetted Parts

303/304, 17-4 PH, hard chrome, Chromex, carbide, Chemical Resistant

 

O-rings, PTFE, nylon, UHMWPE

 

 

Weight

55 kg (120 Lbs) typical with two 7.5L tanks

 

150 kg (330 Lbs) typical with two 60 L tanks

 

 

Sound Power Level

100 psi/30 cpm - 81 dBA

4 in Air Cylinder

50 psi/15cpm – 77 dBA

Measured Per ISO Standard 9614-2

 

 

 

Compressed Air

< 10 scfm typical (varies with cycle times)

 

 

Electrical Power

100-240 V 50/60Hz, 1 phase for machine – 80 Watts

 

208-240V 50/60Hz, 1 phase for heat – 11 kW max.

 

120 or 240 VAC 50/60Hz 1 phase for on-board agitators, 80 Watts

 

240 VAC 50/60Hz 1 phase for off-board agitators, 830 Watts

 

 

312393G

48 of 50

Page 48
Image 48
Graco PR70 important safety instructions Technical Data, Category Data