Rewiring to 440V

Converting the Model G0503 to 440V operation consists of 1) wiring the voltage transformer, 2) rewiring the main motor and the hydraulic pump motor, and 3) replacing the over-load relays with the relays included in the Model G0503 440V Conversion Kit (item #P0503909) that is sold separately.

Electrocution or fire may occur if your con- version does not comply with local and state codes. Have your wiring conversion inspected by a qualified electrician before connecting your machine to power.

To convert the Model G0503 to 440V:

1.Disconnect the resaw from the power source!

2.Open the electrical box and locate the volt- age transformer shown in Figure 68.

6.Remove the wiring covers on the main and hydraulic pump motors.

7.Wire the main and hydraulic pump drive motors as shown on the diagrams on the inside of each motor wire cover. Note—

Figures 69 & 70 are provided for reference and are current at the time that this manual was written. However, always use the dia- gram on the wire cover that comes with your motor! The circled references on the dia- grams represent the labels on the wires.

L1 L2 L3

220V POWER

Figure 69. Main motor 440V wiring.

Voltage Transformer

L1 L2 L3

440V POWER

Siemens Motor

Only

U1, U2 Orange

V1, V2 Black

W1, W2 Red

Figure 68. Inside of electrical box.

3.Move the wire from the 220V terminal on the voltage transformer to the 440V or 480V ter- minal depending on your voltage.

4.Replace the main motor relay with the 440V relay and set the dial to “30.”

5.Replace the hydraulic pump motor relay with the 440V relay and set the dial to “3.6.”

Model G0503 (Mfg. Since 12/08)

Figure 70. Elevation motor 440V wiring.

8.Replace any wire duct covers and motor caps you might have removed during this proce- dure, and close the electrical box door.

9.Have a qualified electrician inspect your work before test running the machine.

-49-

Page 51
Image 51
Grizzly G0503 instruction manual Rewiring to, 220V Power