ELECTRICAL POWER SUPPLY

2000 Autoflow

Electrical Load

Information

The following charts provide infor- mation for the electrician wiring the grain dryer, and are a reference guide for parts. It is recommended that you contact your local power company and have a representatives survey the installation to see that your wiring is compatible with their system and that adequate power is supplied to your unit. Remember that the only thing connected to the recommended service amps should be your grain dryer. Standard elec- trical safety should be used. (Refer to the National Electrical Code Standard Handbook by the National Fire Protection Association). A qualified electrician should make all electrical wiring installations.

 

 

 

 

 

Relay

 

 

Dryer Fan

 

 

Full Load

Motor

Heater

Fuse

 

Size

Voltage

Horsepower

Amps

Starter

Strips

(Slow Blow)

Breaker

 

220v1ph

10-12

48

75

F614B

80

80

 

 

 

 

 

 

 

 

 

208v3ph

10-12

35

40

C400B

60

60

 

 

 

 

 

 

 

 

36"

220v3ph

10-12

33

40

C366B

60

60

 

 

 

 

 

 

 

 

 

380v50hz

10-12

15

30

C180B

30

30

 

 

 

 

 

 

 

 

 

460v3ph

10-12

17

30

C198B

30

30

 

 

 

 

 

 

 

 

 

575v3ph

10-12

15

30

C180B

30

30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

220v1ph

10-16

78

90

F914B

100

100

 

 

 

 

 

 

 

 

 

208v3ph

15

44

60

C460B

60

60

 

 

 

 

 

 

 

 

36"

220v3ph

15

39

60

C400B

60

60

 

 

 

 

 

 

 

 

 

380v50hz

15

27

30

F772B

60

60

 

 

 

 

 

 

 

 

 

460v3ph

15

20

30

C228B

30

30

 

 

 

 

 

 

 

 

 

575v3ph

15

16

30

C198B

30

30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

220v1ph

10-16

78

90

F914B

100

100

 

 

 

 

 

 

 

 

 

208v3ph

15

44

60

C460B

60

60

 

 

 

 

 

 

 

 

42"

220v3ph

15

39

60

C400B

60

60

 

 

 

 

 

 

 

 

 

380v50hz

15

27

30

F772B

60

60

 

 

 

 

 

 

 

 

 

460v3ph

15

20

30

C228B

30

30

 

 

 

 

 

 

 

 

 

575v3ph

15

16

30

C198B

30

30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

208v3ph

20

61

75

F772B

80

80

 

 

 

 

 

 

 

 

 

220v3ph

20

50

60

C500B

80

80

 

 

 

 

 

 

 

 

42"

380v50hz

20

32

40

C366B

60

60

 

 

 

 

 

 

 

 

 

460v3ph

20

25

30

C303B

40

40

 

 

 

 

 

 

 

 

 

575v3ph

20

20

30

C228B

40

40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

208v3ph

30

80

90

F104C

150

150

 

 

 

 

 

 

 

 

 

220v3ph

30

74

75

F772B

150

150

 

 

 

 

 

 

 

 

42"

380v50hz

30

39

40

C440B

80

80

 

 

 

 

 

 

 

 

 

460v3ph

30

37

40

C400B

80

80

 

 

 

 

 

 

 

 

 

575v3ph

30

30

40

C330B

80

80

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

208v3ph

40

108

120

F118C

200

200

 

 

 

 

 

 

 

 

 

220v3ph

40

102

120

F118C

200

200

 

 

 

 

 

 

 

 

42"

380v50hz

40

47

60

C500B

100

100

 

 

 

 

 

 

 

 

 

460v3ph

40

51

60

C550B

100

100

 

 

 

 

 

 

 

 

 

575v3ph

40

40

60

C400B

100

100

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

38

Page 38
Image 38
GSI Outdoors 2TFC, 2TAF installation instructions Electrical Load Information