ELECTRICAL POWER SUPPLY

2000 Autoflow

Fill System Control Box Electrical Load Information

The following charts provide information for the electrician wiring the grain dryer, and are a reference guide for parts. It is recommended that you contact your local power company and have a representative survey the installation to see that your wiring is compatible with their system and that adequate power is supplied to your unit. Remember that the only thing connected to the recommended service amps should be your grain dryer. Standard electrical safety should be used. (Refer to the National Electrical Code Standard handbook by the National Fire Protection Association.) A qualified electrician should make all electrical wiring installations.

 

 

 

 

Relay

Fill System

 

Full Load

Motor

Heater

HP

Voltage

Amps

Starter

Strips

 

220v1ph

13

30

C137B

 

 

 

 

 

3 HP

220v3ph

7

30

C104B

 

 

 

 

 

 

380v50hz

4

30

C630A

 

 

 

 

 

 

460v3ph

4

30

C630A

 

 

 

 

 

 

575v3ph

3

30

C630A

 

 

 

 

 

 

 

 

 

 

 

220v1ph

21

30

C228B

 

 

 

 

 

5 HP

220v3ph

12

30

C163B

 

 

 

 

 

 

380v50hz

7

30

C955A

 

 

 

 

 

 

460v3ph

6

30

C778A

 

 

 

 

 

 

575v3ph

5

30

C630A

 

 

 

 

 

 

 

 

 

 

 

220v1ph

32

40

C303B

 

 

 

 

 

7.5 HP

220v3ph

18

30

C228B

 

 

 

 

 

 

380v50hz

11

30

C151B

 

 

 

 

 

 

460v3ph

9

30

C125B

 

 

 

 

 

 

575v3ph

7

30

C955B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Relay

 

 

Fill System

 

Full Load

Motor

Heater

 

 

HP

Voltage

Amps

Starter

Strips

 

 

 

220v1ph

42

60

C366B

 

 

 

 

 

 

 

 

 

10 HP

220v3ph

25

30

C303B

 

 

 

 

 

 

 

 

 

 

380v50hz

14

30

C180B

 

 

 

 

 

 

 

 

 

 

460v3ph

12

30

C163B

 

 

 

 

 

 

 

 

 

 

575v3ph

9

30

C137B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

220v1ph

64

75

F658B

 

 

 

 

 

 

 

 

 

15 HP

220v3ph

37

40

C400B

 

 

 

 

 

 

 

 

 

 

380v50hz

21

30

C273B

 

 

 

 

 

 

 

 

 

 

460v3ph

18

30

C214B

 

 

 

 

 

 

 

 

 

 

575v3ph

14

30

C180B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

220v3ph

49

60

C500B

 

 

 

 

 

 

 

 

 

20 HP

380v50hz

28

40

C330B

 

 

 

 

 

 

 

 

 

 

460v3ph

23

30

C303B

 

 

 

 

 

 

 

 

 

 

575v3ph

19

30

C228B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

220v3ph

61

75

F719B

 

 

 

 

 

 

 

 

 

25 HP

380v50hz

35

40

C400B

 

 

 

 

 

 

 

 

 

 

460v3ph

29

40

C330B

 

 

 

 

 

 

 

 

 

 

575v3ph

23

30

C273B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

220v3ph

73

75

F772B

 

 

 

 

 

 

 

 

 

30 HP

380v50hz

43

60

C440B

 

 

 

 

 

 

 

 

 

 

460v3ph

35

40

C400B

 

 

 

 

 

 

 

 

 

 

575v3ph

28

40

C330B

 

 

 

 

 

 

 

 