Assembly

2. WIRE THE COLLECTOR RING

Electrical controls and wiring should be installed by a qualified electrician. The motor disconnect switches and conductor cables should comply with the National Electrical code and any local codes which apply. Reset and motor starting stations should be located so that the operator can see that all personnel are clear of the equipment.

Note:The liquid-tight flex conduit may need to be trimmed to length.

A.Attach the 1" liquid-tight flex conduit coupling to one end of the 1" x 16" liquid-tight flex conduit.

B.Attach the 1" x 45 degree liquid-tight flex conduit coupling to the other end of the 1" x 16" liquid tight flex conduit.

C.Remove the protective housing from the collector ring.

D.Feed the multi-conductor cord through the conduit assembly and the 1" conduit hub on the collector ring.

E.Attach the 1" x 45 degree liquid-tight flex conduit coupling to the 1" conduit hub on the collector ring. Be sure to turn the conduit assembly down .

1" x 45 degree flex conduit coupling

multi-conductor cord

collector ring hub

1" x 16" flex conduit

 

1" flex conduit coupling

PNEG-970S2 Hopper w/ Collector Ring

19

Page 19
Image 19
GSI Outdoors PNEG-970 operation manual Wire the Collector Ring