Selecting the Correct Tip

Selecting the Correct Tip

FinishPro 390

Material

Oil Based

Water Based

Tip Size

Fluid Setting

Air Setting

 

 

 

 

 

 

 

 

 

 

 

 

Stains/Varnish

.008/.010

500-700 psi

1/2 turn

 

 

 

 

(30-50 bar)

 

 

 

 

 

 

 

Lacquers

.008/.010

700-1000 psi

1/2 turn

 

 

 

 

(50-70 bar)

 

 

 

 

 

 

 

DTM

 

.010/.012

900-1200 psi

1 turn.

 

 

 

 

(60-80 bar)

 

 

 

 

 

 

 

DTM (Alkyd)

 

.014/.016

1800-2400 psi

2 turns

 

 

 

 

(125-165 bar)

 

 

 

 

 

 

 

Enamels

.014/.016

1800-2400 psi

3 turns

 

 

 

 

(125-165 bar)

 

 

 

 

 

 

 

FinishPro 395

Material

Oil Based

Water Based

Tip Size

Fluid Setting

Air Setting

 

 

 

 

 

 

 

 

 

 

 

 

Stains/Varnish

.008/.010

500-700 psi

10 - 15 psi

 

 

 

 

(30-50 bar)

(0.8 - 1.0 bar)

 

 

 

 

 

 

Lacquers

.008/.010

700-1000 psi

10 - 15 psi

 

 

 

 

(50-70 bar)

(0.8 - 1.0 bar)

 

 

 

 

 

 

DTM

 

.010/.012

900-1200 psi

15 - 20 psi

 

 

 

 

(60-80 bar)

(1.0 - 1.5 bar)

 

 

 

 

 

 

DTM (Alkyd)

 

.014/.016

1800-2400 psi

20 - 25 psi

 

 

 

 

(125-165 bar)

(1.5 - 1.8 bar)

 

 

 

 

 

 

Enamels

.014/.016

1800-2400 psi

25 - 30 psi

 

 

 

 

(125-165 bar)

(1.8 - 2.0 bar)

 

 

 

 

 

 

311905B

27

Page 27
Image 27
Haier 390 important safety instructions Selecting the Correct Tip, FinishPro