B. Installing Firestops and Horizontal Termination Cap
| WARNING | TRIM HEAT | ||
|
|
| HEAT SHIELD | |
|
|
| SHIELD IF TOO | |
| Fire Risk |
| LONG, ADD TO | |
| Exhaust Fumes Risk |
| SHIELD IF TOO | |
|
| SHORT | ||
| Impaired Performance of Appliance |
| ||
| • Ensure flue components are locked together correctly. | WALL SHIELD | ||
| • Pipe may separate if not properly joined. | FIRESTOP | ||
| (EXTERIOR) | |||
|
|
| WALL SHIELD | |
For Horizontal Runs - Wall shield firestops are REQUIRED | FIRESTOP | |||
(INTERIOR) | ||||
on both sides of a combustible wall through which the flue |
| |||
passes. |
|
| ||
NOTE: Model |
| |||
wall shield firestop on an exterior combustible wall as |
| |||
the shield is built into this termination cap assembly. | Figure 8.3 Heat Shield, Interior & Exterior Wall Shield Firestops | |||
To install wall shield firestops for horizontal runs that pass | ||||
| ||||
through either interior or exterior walls: |
| |||
Cut a 25.4 cm x 25.4 cm hole for |
| |||
center of the framing hole is 2.54 cm above the center of |
| |||
the horizontal flue pipe. |
| WARNING | ||
• | Position the wall shield firestops on both sides of the | |||
| hole previously cut and secure the wall shield firestops | Fire Risk. | ||
| with nails or screws. |
| ||
|
| Explosion Risk. | ||
• | The heat shields of the wall shield firestops MUST BE | Do NOT pack insulation or other | ||
| placed towards the top of the hole. | combustibles between firestops. | ||
• | Continue the flue run through the wall shield firestops. | • ALWAYS maintain specified clearances around venting | ||
|
|
| and firestop systems. | |
|
|
| • Install firestops as specified. | |
| 25.4 cm |
| Failure to keep insulation or other material away from flue | |
|
| FRAMED HOLE CENTER LINE | pipe may cause fire. | |
|
|
| ||
|
|
| Installing the Horizontal Termination Cap | |
| 2.54 cm | PIPE CENTER LINE | Flue termination must not be recessed in the wall. Siding | |
| may be brought to the edge of the cap base. | |||
|
|
| ||
|
|
| Flash and seal as appropriate for siding material at outside | |
|
| 25.4 cm | edges of cap. | |
| FLUE PIPE |
| WARNING | |
| Figure 8.2 Hole and Flue Pipe |
| ||
|
|
| Do NOT connect a pipe section to a termination cap without using | |
|
|
| the telescoping flue section found on the termination cap. | |
|
|
| NOTE: Where required, an exterior wall flashing is available. | |
|
|
| When penetrating a brick wall, a brick extension kit is avail- | |
|
|
| able for framing the brick. |
Heat & Glo • | 19 |