Heat & Glo • Soho-CE • 2111-900 Rev. D • 6/07
10
5
5 Flue Information and Diagrams
Fire Hazard.
Explosion Risk.
Asphyxiation Risk.
Do NOT connect this gas appliance to a chimney
ue serving a separate solid-fuel or gas burning
appliance.
Vent this appliance directly outside.
• Use separate ue system for this appliance.
May impair safe operation of this appliance or
other appliances connected to the ue.
CAUTION
ALL ue con guration speci cations MUST be followed.
This product is tested and listed to these speci cations.
Appliance performance will suffer if speci cations are not
followed.

B. Use of Elbows

Diagonal runs have both vertical and horizontal ue as-
pects when calculating the effects. Use the rise for the
vertical aspect and the run for the horizontal aspect (see
Figure 5.1).
Two 45º elbows may be used in place of one 90º elbow. On
45º runs, 30.5 cm of diagonal is equal to 21.6 centimeters
horizontal run and 21.6 centimeters vertical run. A length
of straight pipe is allowed between two 45º elbows (see
Flue diagrams).
Figure 5.1

A. Flue Table Key

The abbreviations listed in this ue table key are used in
the ue diagrams.

C. Measuring Standards

Vertical and horizontal measurements listed in the ue
diagrams were made using the following standards.
1. Pipe measurements are from center line to center line.
2. Measurements are made from the appliance outer wrap,
not from the standoffs.
3. Horizontal terminations are measured to the end of
termination cap.
4. Vertical terminations are measured to bottom of termi-
nation cap.
5. Horizontal pipe installed level with no slope up or
down.
Symbol Description
V1First section (closest to appliance) of vertical length
V2Second section of vertical length
H1First section (closest to appliance) of horizontal length
H2Second section of horizontal length
Horizontal
Vertical
21.6 cm
21.6 cm

30.5 cm